<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>SLC 500 AC Digital Input Module - Excellent PLC</title>
	<atom:link href="https://www.excellentplc.com/tag/slc-500-ac-digital-input-module/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.excellentplc.com/tag/slc-500-ac-digital-input-module/</link>
	<description></description>
	<lastBuildDate>Thu, 16 Apr 2026 09:58:03 +0000</lastBuildDate>
	<language>zh-Hans</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.excellentplc.com/wp-content/uploads/2025/08/cropped-cropped-logo-192x192-1-32x32.jpg</url>
	<title>SLC 500 AC Digital Input Module - Excellent PLC</title>
	<link>https://www.excellentplc.com/tag/slc-500-ac-digital-input-module/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Allen Bradley 1746-IA8 SLC 500 AC Digital Input Module</title>
		<link>https://www.excellentplc.com/allen-bradley-1746-ia8-slc-500-ac-digital-input-module/</link>
					<comments>https://www.excellentplc.com/allen-bradley-1746-ia8-slc-500-ac-digital-input-module/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 16 Apr 2026 09:58:03 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[1746-IA8]]></category>
		<category><![CDATA[Allen Bradley 1746-IA8]]></category>
		<category><![CDATA[SLC 500 AC Digital Input Module]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=127375</guid>

					<description><![CDATA[<p>Product Introduction The Allen Bradley 1746-IA8 SLC 500 [&#8230;]</p>
<p><a href="https://www.excellentplc.com/allen-bradley-1746-ia8-slc-500-ac-digital-input-module/">Allen Bradley 1746-IA8 SLC 500 AC Digital Input Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-section-id="wmrafh" data-start="4" data-end="28"><img fetchpriority="high" decoding="async" class="alignnone size-full wp-image-127390" src="https://www.excellentplc.com/wp-content/uploads/2026/04/1746-IA8-1.jpg" alt="Allen Bradley 1746-IA8 SLC 500 AC Digital Input Module" width="800" height="800"></h3>
<h3 data-section-id="wmrafh" data-start="4" data-end="28">Product Introduction</h3>
<p data-start="29" data-end="374">The Allen Bradley 1746-IA8 SLC 500 AC Digital Input Module is an 8-channel AC input module designed for integration within the SLC 500 automation platform by <span class="hover:entity-accent entity-underline inline cursor-pointer align-baseline"><span class="whitespace-normal">Rockwell Automation</span></span>. It is built to reliably detect and transmit AC input signals from field devices to the controller, ensuring stable monitoring of discrete processes.</p>
<p data-start="376" data-end="697">This module operates with 100/120 VAC input signals, making it suitable for applications where AC-powered devices such as push buttons, limit switches, and relays are commonly used. Its open-style design allows for efficient heat dissipation while maintaining dependable operation in standard industrial control cabinets.</p>
<p data-start="699" data-end="899">With 8 input points grouped for simplified wiring, the 1746-IA8 provides a practical and cost-effective solution for systems that require AC signal acquisition within SLC 500 rack-based architectures.</p>
<hr data-start="901" data-end="904">
<h3 data-section-id="1dqbs77" data-start="905" data-end="931">Product Specifications</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="932" data-end="1686">
<thead data-start="932" data-end="957">
<tr data-start="932" data-end="957">
<th class="" data-start="932" data-end="948" data-col-size="sm"><strong data-start="934" data-end="947">Parameter</strong></th>
<th class="" data-start="948" data-end="957" data-col-size="sm">Value</th>
</tr>
</thead>
<tbody data-start="983" data-end="1686">
<tr data-start="983" data-end="1036">
<td data-start="983" data-end="1001" data-col-size="sm"><strong data-start="985" data-end="1000">Module Type</strong></td>
<td data-start="1001" data-end="1036" data-col-size="sm">SLC 500 AC Digital Input Module</td>
</tr>
<tr data-start="1037" data-end="1068">
<td data-start="1037" data-end="1054" data-col-size="sm"><strong data-start="1039" data-end="1053">Input Type</strong></td>
<td data-start="1054" data-end="1068" data-col-size="sm">Digital AC</td>
</tr>
<tr data-start="1069" data-end="1104">
<td data-start="1069" data-end="1092" data-col-size="sm"><strong data-start="1071" data-end="1091">Number of Inputs</strong></td>
<td data-start="1092" data-end="1104" data-col-size="sm">8 Points</td>
</tr>
<tr data-start="1105" data-end="1146">
<td data-start="1105" data-end="1131" data-col-size="sm"><strong data-start="1107" data-end="1130">Input Voltage Range</strong></td>
<td data-start="1131" data-end="1146" data-col-size="sm">100/120 VAC</td>
</tr>
<tr data-start="1147" data-end="1181">
<td data-start="1147" data-end="1169" data-col-size="sm"><strong data-start="1149" data-end="1168">Frequency Range</strong></td>
<td data-start="1169" data-end="1181" data-col-size="sm">50/60 Hz</td>
</tr>
<tr data-start="1182" data-end="1220">
<td data-start="1182" data-end="1206" data-col-size="sm"><strong data-start="1184" data-end="1205">Backplane Current</strong></td>
<td data-start="1206" data-end="1220" data-col-size="sm">50 mA @ 5V</td>
</tr>
<tr data-start="1221" data-end="1270">
<td data-start="1221" data-end="1247" data-col-size="sm"><strong data-start="1223" data-end="1246">Input Configuration</strong></td>
<td data-start="1247" data-end="1270" data-col-size="sm">8 Points per Module</td>
</tr>
<tr data-start="1271" data-end="1310">
<td data-start="1271" data-end="1289" data-col-size="sm"><strong data-start="1273" data-end="1288">Signal Type</strong></td>
<td data-start="1289" data-end="1310" data-col-size="sm">AC Discrete Input</td>
</tr>
<tr data-start="1311" data-end="1361">
<td data-start="1311" data-end="1327" data-col-size="sm"><strong data-start="1313" data-end="1326">Isolation</strong></td>
<td data-start="1327" data-end="1361" data-col-size="sm">Electrical Isolation Supported</td>
</tr>
<tr data-start="1362" data-end="1405">
<td data-start="1362" data-end="1386" data-col-size="sm"><strong data-start="1364" data-end="1385">Status Indicators</strong></td>
<td data-start="1386" data-end="1405" data-col-size="sm">LED per Channel</td>
</tr>
<tr data-start="1406" data-end="1438">
<td data-start="1406" data-end="1424" data-col-size="sm"><strong data-start="1408" data-end="1423">Design Type</strong></td>
<td data-start="1424" data-end="1438" data-col-size="sm">Open Style</td>
</tr>
<tr data-start="1439" data-end="1490">
<td data-start="1439" data-end="1454" data-col-size="sm"><strong data-start="1441" data-end="1453">Mounting</strong></td>
<td data-start="1454" data-end="1490" data-col-size="sm">Rack Mountable (SLC 500 Chassis)</td>
</tr>
<tr data-start="1491" data-end="1532">
<td data-start="1491" data-end="1519" data-col-size="sm"><strong data-start="1493" data-end="1518">Operating Temperature</strong></td>
<td data-start="1519" data-end="1532" data-col-size="sm">0 to 60&deg;C</td>
</tr>
<tr data-start="1533" data-end="1574">
<td data-start="1533" data-end="1559" data-col-size="sm"><strong data-start="1535" data-end="1558">Storage Temperature</strong></td>
<td data-start="1559" data-end="1574" data-col-size="sm">-40 to 85&deg;C</td>
</tr>
<tr data-start="1575" data-end="1614">
<td data-start="1575" data-end="1590" data-col-size="sm"><strong data-start="1577" data-end="1589">Humidity</strong></td>
<td data-start="1590" data-end="1614" data-col-size="sm">5&ndash;95% non-condensing</td>
</tr>
<tr data-start="1615" data-end="1660">
<td data-start="1615" data-end="1632" data-col-size="sm"><strong data-start="1617" data-end="1631">Dimensions</strong></td>
<td data-start="1632" data-end="1660" data-col-size="sm">144.5 &times; 34.6 &times; 130.18 mm</td>
</tr>
<tr data-start="1661" data-end="1686">
<td data-start="1661" data-end="1674" data-col-size="sm"><strong data-start="1663" data-end="1673">Weight</strong></td>
<td data-start="1674" data-end="1686" data-col-size="sm">0.204 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1688" data-end="1691">
<h3 data-section-id="wggvqn" data-start="1692" data-end="1708">Applications</h3>
<p data-start="1710" data-end="1797">&#9679; Used for <strong data-start="1721" data-end="1752">monitoring AC input signals</strong> such as push buttons and selector switches</p>
<p data-start="1799" data-end="1885">&#9679; Suitable for <strong data-start="1814" data-end="1843">industrial control panels</strong> where AC-powered field devices are used</p>
<p data-start="1887" data-end="1972">&#9679; Applied in <strong data-start="1900" data-end="1925">manufacturing systems</strong>, providing reliable discrete input detection</p>
<p data-start="1974" data-end="2067">&#9679; Common in <strong data-start="1986" data-end="2018">process control environments</strong>, where stable AC signal monitoring is required</p>
<p data-start="2069" data-end="2154">&#9679; Ideal for <strong data-start="2081" data-end="2104">equipment retrofits</strong>, maintaining compatibility with SLC 500 systems</p>
<p data-start="2156" data-end="2241">&#9679; Used in <strong data-start="2166" data-end="2195">material handling systems</strong>, detecting operational states and positions</p>
<hr data-start="2243" data-end="2246">
<h3 data-section-id="1l3n95q" data-start="2247" data-end="2261">Advantages</h3>
<p data-start="2263" data-end="2347">&#9679; Supports <strong data-start="2274" data-end="2305">standard 100/120 VAC inputs</strong>, widely used in industrial environments</p>
<p data-start="2349" data-end="2426">&#9679; Provides <strong data-start="2360" data-end="2380">8 input channels</strong>, suitable for compact system configurations</p>
<p data-start="2428" data-end="2496">&#9679; Features <strong data-start="2439" data-end="2460">open-style design</strong> for efficient thermal performance</p>
<p data-start="2498" data-end="2577">&#9679; Includes <strong data-start="2509" data-end="2539">LED indicators per channel</strong>, allowing quick status verification</p>
<p data-start="2579" data-end="2657">&#9679; Ensures <strong data-start="2589" data-end="2616">stable signal detection</strong>, even in electrically noisy conditions</p>
<p data-start="2659" data-end="2734">&#9679; Fully compatible with <strong data-start="2683" data-end="2707">SLC 500 rack systems</strong>, simplifying integration</p>
</body></html>
<p><a href="https://www.excellentplc.com/allen-bradley-1746-ia8-slc-500-ac-digital-input-module/">Allen Bradley 1746-IA8 SLC 500 AC Digital Input Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.excellentplc.com/allen-bradley-1746-ia8-slc-500-ac-digital-input-module/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Allen Bradley 1746-IA4 SLC 500 AC Digital Input Module</title>
		<link>https://www.excellentplc.com/allen-bradley-1746-ia4-input-module/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 18 Feb 2026 06:07:34 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[1746-IA4]]></category>
		<category><![CDATA[Allen Bradley 1746-IA4]]></category>
		<category><![CDATA[SLC 500 AC Digital Input Module]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=117763</guid>

					<description><![CDATA[<p>Product Introduction The Allen Bradley 1746-IA4 SLC 500 [&#8230;]</p>
<p><a href="https://www.excellentplc.com/allen-bradley-1746-ia4-input-module/">Allen Bradley 1746-IA4 SLC 500 AC Digital Input Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-start="208" data-end="232"><img decoding="async" class="alignnone size-full wp-image-117764" src="https://www.excellentplc.com/wp-content/uploads/2026/01/1746-IA4-1.jpg" alt="Allen Bradley 1746-IA4 SLC 500 AC Digital Input Module" width="800" height="800"></h3>
<h3 data-start="208" data-end="232">Product Introduction</h3>
<p data-start="234" data-end="517">The <strong data-start="238" data-end="277">Allen Bradley 1746-IA4 SLC 500 AC Digital Input Module</strong>&nbsp;is a compact digital input module designed for integration with SLC 500 series PLCs. It provides four discrete input channels for monitoring AC devices and switches, delivering reliable signal detection for industrial automation systems.</p>
<p data-start="519" data-end="821">The module supports standard 120 VAC input signals at 50/60 Hz and is optimized for precise, low-current detection, making it suitable for sensing applications in manufacturing, process control, and machine automation environments. Its small footprint allows for efficient use of control panel space.</p>
<hr data-start="823" data-end="826">
<h3 data-start="828" data-end="854">Product Specifications</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="856" data-end="1560">
<thead data-start="856" data-end="891">
<tr data-start="856" data-end="891">
<th data-start="856" data-end="872" data-col-size="sm"><strong data-start="858" data-end="871">Parameter</strong></th>
<th data-start="872" data-end="891" data-col-size="md"><strong data-start="874" data-end="889">Description</strong></th>
</tr>
</thead>
<tbody data-start="926" data-end="1560">
<tr data-start="926" data-end="969">
<td data-start="926" data-end="945" data-col-size="sm"><strong data-start="928" data-end="944">Product Type</strong></td>
<td data-start="945" data-end="969" data-col-size="md">Digital Input Module</td>
</tr>
<tr data-start="970" data-end="994">
<td data-start="970" data-end="982" data-col-size="sm"><strong data-start="972" data-end="981">Model</strong></td>
<td data-start="982" data-end="994" data-col-size="md">1746-IA4</td>
</tr>
<tr data-start="995" data-end="1031">
<td data-start="995" data-end="1014" data-col-size="sm"><strong data-start="997" data-end="1013">Manufacturer</strong></td>
<td data-start="1014" data-end="1031" data-col-size="md">Allen Bradley</td>
</tr>
<tr data-start="1032" data-end="1096">
<td data-start="1032" data-end="1047" data-col-size="sm"><strong data-start="1034" data-end="1046">Function</strong></td>
<td data-start="1047" data-end="1096" data-col-size="md">Provides digital input signals to PLC systems</td>
</tr>
<tr data-start="1097" data-end="1128">
<td data-start="1097" data-end="1116" data-col-size="sm"><strong data-start="1099" data-end="1115">Total Points</strong></td>
<td data-start="1116" data-end="1128" data-col-size="md">4 points</td>
</tr>
<tr data-start="1129" data-end="1157">
<td data-start="1129" data-end="1146" data-col-size="sm"><strong data-start="1131" data-end="1145">Input Type</strong></td>
<td data-start="1146" data-end="1157" data-col-size="md">Digital</td>
</tr>
<tr data-start="1158" data-end="1199">
<td data-start="1158" data-end="1178" data-col-size="sm"><strong data-start="1160" data-end="1177">Input Voltage</strong></td>
<td data-start="1178" data-end="1199" data-col-size="md">120 VAC, 50/60 Hz</td>
</tr>
<tr data-start="1200" data-end="1259">
<td data-start="1200" data-end="1220" data-col-size="sm"><strong data-start="1202" data-end="1219">Input Current</strong></td>
<td data-start="1220" data-end="1259" data-col-size="md">35 mA @ 5 VDC for sensing circuitry</td>
</tr>
<tr data-start="1260" data-end="1310">
<td data-start="1260" data-end="1287" data-col-size="sm"><strong data-start="1262" data-end="1286">Compatible Platforms</strong></td>
<td data-start="1287" data-end="1310" data-col-size="md">SLC 500 series PLCs</td>
</tr>
<tr data-start="1311" data-end="1357">
<td data-start="1311" data-end="1326" data-col-size="sm"><strong data-start="1313" data-end="1325">Mounting</strong></td>
<td data-start="1326" data-end="1357" data-col-size="md">DIN rail or SLC 500 chassis</td>
</tr>
<tr data-start="1358" data-end="1416">
<td data-start="1358" data-end="1374" data-col-size="sm"><strong data-start="1360" data-end="1373">Isolation</strong></td>
<td data-start="1374" data-end="1416" data-col-size="md">Optical isolation for input protection</td>
</tr>
<tr data-start="1417" data-end="1496">
<td data-start="1417" data-end="1437" data-col-size="sm"><strong data-start="1419" data-end="1436">Response Time</strong></td>
<td data-start="1437" data-end="1496" data-col-size="md">Standard digital input response suitable for monitoring</td>
</tr>
<tr data-start="1497" data-end="1535">
<td data-start="1497" data-end="1514" data-col-size="sm"><strong data-start="1499" data-end="1513">Dimensions</strong></td>
<td data-start="1514" data-end="1535" data-col-size="md">144.5 &times; 34.6 &times; 130.18 mm</td>
</tr>
<tr data-start="1536" data-end="1560">
<td data-start="1536" data-end="1549" data-col-size="sm"><strong data-start="1538" data-end="1548">Weight</strong></td>
<td data-start="1549" data-end="1560" data-col-size="md">0.17 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1562" data-end="1565">
<h3 data-start="1567" data-end="1583">Applications</h3>
<p data-start="1585" data-end="1661">&bull; <strong data-start="1587" data-end="1609">Digital monitoring</strong> of AC devices and switches in SLC 500 PLC systems</p>
<p data-start="1663" data-end="1751">&bull; <strong data-start="1665" data-end="1690">Industrial automation</strong> including assembly lines, material handling, and packaging</p>
<p data-start="1753" data-end="1821">&bull; <strong data-start="1755" data-end="1774">Machine control</strong> requiring low-current discrete input sensing</p>
<p data-start="1823" data-end="1899">&bull; <strong data-start="1825" data-end="1847">Process monitoring</strong> where precise detection of AC signals is required</p>
<p data-start="1901" data-end="1975">&bull; <strong data-start="1903" data-end="1929">Compact control panels</strong> where space-saving input modules are needed</p>
<p data-start="1977" data-end="2072">&bull; <strong data-start="1979" data-end="2027">Integration with distributed control systems</strong> for efficient wiring and modular expansion</p>
<hr data-start="2074" data-end="2077">
<h3 data-start="2079" data-end="2093">Advantages</h3>
<p data-start="2095" data-end="2195">&bull; <strong data-start="2097" data-end="2123">Compact 4-point design</strong>, conserving panel space while providing essential input functionality</p>
<p data-start="2197" data-end="2284">&bull; <strong data-start="2199" data-end="2235">Supports standard 120 VAC inputs</strong>, compatible with typical industrial AC devices</p>
<p data-start="2286" data-end="2388">&bull; <strong data-start="2288" data-end="2309">Optical isolation</strong>, ensuring reliable operation and protecting PLC inputs from electrical noise</p>
<p data-start="2390" data-end="2468">&bull; <strong data-start="2392" data-end="2434">Direct compatibility with SLC 500 PLCs</strong>, simplifying system integration</p>
<p data-start="2470" data-end="2559">&bull; <strong data-start="2472" data-end="2495">Low current sensing</strong>, minimizing load on input circuits while maintaining accuracy</p>
<p data-start="2561" data-end="2659">&bull; <strong data-start="2563" data-end="2596">Robust industrial performance</strong>, suitable for continuous operation in demanding environments</p>
<p data-start="2661" data-end="2749">&bull; <strong data-start="2663" data-end="2692">Flexible mounting options</strong>, suitable for DIN rail or SLC 500 chassis installation</p>
</body></html>
<p><a href="https://www.excellentplc.com/allen-bradley-1746-ia4-input-module/">Allen Bradley 1746-IA4 SLC 500 AC Digital Input Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Allen Bradley 1746-1A16 SLC 500 AC Digital Input Module</title>
		<link>https://www.excellentplc.com/allen-bradley-1746-1a16-digital-input-module/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 21 Jan 2026 08:07:52 +0000</pubDate>
				<category><![CDATA[Allen Bradley]]></category>
		<category><![CDATA[1746-1A16]]></category>
		<category><![CDATA[Allen Bradley 1746-1A16]]></category>
		<category><![CDATA[SLC 500 AC Digital Input Module]]></category>
		<guid isPermaLink="false">https://www.excellentplc.com/?p=117363</guid>

					<description><![CDATA[<p>Product Introduction The Allen Bradley 1746-IA16 Digita [&#8230;]</p>
<p><a href="https://www.excellentplc.com/allen-bradley-1746-1a16-digital-input-module/">Allen Bradley 1746-1A16 SLC 500 AC Digital Input Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></description>
										<content:encoded><![CDATA[<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.0 Transitional//EN" "http://www.w3.org/TR/REC-html40/loose.dtd">
<html><body><h3 data-start="4" data-end="28"><img decoding="async" class="alignnone size-full wp-image-117364" src="https://www.excellentplc.com/wp-content/uploads/2026/01/1746-1A16-2.jpg" alt="Allen Bradley 1746-1A16 SLC 500 AC Digital Input Module" width="800" height="800"></h3>
<h3 data-start="4" data-end="28">Product Introduction</h3>
<p data-start="30" data-end="297">The <strong data-start="34" data-end="82">Allen Bradley 1746-IA16 Digital Input Module</strong> is an <strong data-start="89" data-end="116">AC digital input module</strong> designed for the <strong data-start="134" data-end="158">SLC 500 PLC platform</strong>. It provides <strong data-start="172" data-end="205">16 discrete AC input channels</strong>, enabling reliable monitoring of field-level signals operating in the <strong data-start="276" data-end="296">85&ndash;132V AC range</strong>.</p>
<p data-start="299" data-end="634">This module is engineered to interface directly with industrial AC devices such as switches, sensors, and control contacts. Its <strong data-start="427" data-end="462">open-style chassis construction</strong> allows seamless installation into SLC 500 racks while maintaining consistent electrical connectivity and dependable signal processing under demanding operating conditions.</p>
<hr data-start="636" data-end="639">
<h3 data-start="640" data-end="666">Product Specifications</h3>
<div class="TyagGW_tableContainer">
<div class="group TyagGW_tableWrapper flex flex-col-reverse w-fit" tabindex="-1">
<table class="w-fit min-w-(--thread-content-width)" data-start="668" data-end="1461">
<thead data-start="668" data-end="699">
<tr data-start="668" data-end="699">
<th data-start="668" data-end="684" data-col-size="sm"><strong data-start="670" data-end="683">Parameter</strong></th>
<th data-start="684" data-end="699" data-col-size="sm">Description</th>
</tr>
</thead>
<tbody data-start="731" data-end="1461">
<tr data-start="731" data-end="774">
<td data-start="731" data-end="750" data-col-size="sm"><strong data-start="733" data-end="749">Product Type</strong></td>
<td data-start="750" data-end="774" data-col-size="sm">Digital Input Module</td>
</tr>
<tr data-start="775" data-end="830">
<td data-start="775" data-end="796" data-col-size="sm"><strong data-start="777" data-end="795">Product Series</strong></td>
<td data-start="796" data-end="830" data-col-size="sm">SLC 500 (Bulletin 1746 / 1747)</td>
</tr>
<tr data-start="831" data-end="865">
<td data-start="831" data-end="852" data-col-size="sm"><strong data-start="833" data-end="851">Component Type</strong></td>
<td data-start="852" data-end="865" data-col-size="sm">PLC &amp; I/O</td>
</tr>
<tr data-start="866" data-end="898">
<td data-start="866" data-end="885" data-col-size="sm"><strong data-start="868" data-end="884">Model Number</strong></td>
<td data-start="885" data-end="898" data-col-size="sm">1746-IA16</td>
</tr>
<tr data-start="899" data-end="928">
<td data-start="899" data-end="917" data-col-size="sm"><strong data-start="901" data-end="916">Signal Type</strong></td>
<td data-start="917" data-end="928" data-col-size="sm">Digital</td>
</tr>
<tr data-start="929" data-end="966">
<td data-start="929" data-end="960" data-col-size="sm"><strong data-start="931" data-end="959">Number of Digital Inputs</strong></td>
<td data-start="960" data-end="966" data-col-size="sm">16</td>
</tr>
<tr data-start="967" data-end="998">
<td data-start="967" data-end="992" data-col-size="sm"><strong data-start="969" data-end="991">Digital Input Type</strong></td>
<td data-start="992" data-end="998" data-col-size="sm">AC</td>
</tr>
<tr data-start="999" data-end="1036">
<td data-start="999" data-end="1025" data-col-size="sm"><strong data-start="1001" data-end="1024">Rated Input Voltage</strong></td>
<td data-start="1025" data-end="1036" data-col-size="sm">120V AC</td>
</tr>
<tr data-start="1037" data-end="1077">
<td data-start="1037" data-end="1063" data-col-size="sm"><strong data-start="1039" data-end="1062">Digital Input Range</strong></td>
<td data-start="1063" data-end="1077" data-col-size="sm">85&ndash;132V AC</td>
</tr>
<tr data-start="1078" data-end="1120">
<td data-start="1078" data-end="1112" data-col-size="sm"><strong data-start="1080" data-end="1111">Operating Temperature (Min)</strong></td>
<td data-start="1112" data-end="1120" data-col-size="sm">0 &deg;C</td>
</tr>
<tr data-start="1121" data-end="1164">
<td data-start="1121" data-end="1155" data-col-size="sm"><strong data-start="1123" data-end="1154">Operating Temperature (Max)</strong></td>
<td data-start="1155" data-end="1164" data-col-size="sm">60 &deg;C</td>
</tr>
<tr data-start="1165" data-end="1207">
<td data-start="1165" data-end="1197" data-col-size="sm"><strong data-start="1167" data-end="1196">Storage Temperature (Min)</strong></td>
<td data-start="1197" data-end="1207" data-col-size="sm">-40 &deg;C</td>
</tr>
<tr data-start="1208" data-end="1249">
<td data-start="1208" data-end="1240" data-col-size="sm"><strong data-start="1210" data-end="1239">Storage Temperature (Max)</strong></td>
<td data-start="1240" data-end="1249" data-col-size="sm">85 &deg;C</td>
</tr>
<tr data-start="1250" data-end="1309">
<td data-start="1250" data-end="1282" data-col-size="sm"><strong data-start="1252" data-end="1281">Maximum Relative Humidity</strong></td>
<td data-start="1282" data-end="1309" data-col-size="sm">95% RH (non-condensing)</td>
</tr>
<tr data-start="1310" data-end="1352">
<td data-start="1310" data-end="1330" data-col-size="sm"><strong data-start="1312" data-end="1329">Chassis Style</strong></td>
<td data-start="1330" data-end="1352" data-col-size="sm">Open Style Chassis</td>
</tr>
<tr data-start="1353" data-end="1396">
<td data-start="1353" data-end="1375" data-col-size="sm"><strong data-start="1355" data-end="1374">Mounting Method</strong></td>
<td data-start="1375" data-end="1396" data-col-size="sm">SLC 500 backplane</td>
</tr>
<tr data-start="1397" data-end="1435">
<td data-start="1397" data-end="1414" data-col-size="sm"><strong data-start="1399" data-end="1413">Dimensions</strong></td>
<td data-start="1414" data-end="1435" data-col-size="sm">144.5 &times; 34.6 &times; 130.18 mm</td>
</tr>
<tr data-start="1436" data-end="1461">
<td data-start="1436" data-end="1449" data-col-size="sm"><strong data-start="1438" data-end="1448">Weight</strong></td>
<td data-start="1449" data-end="1461" data-col-size="sm">0.181 kg</td>
</tr>
</tbody>
</table>
</div>
</div>
<hr data-start="1463" data-end="1466">
<h3 data-start="1467" data-end="1483">Applications</h3>
<p data-start="1485" data-end="1568">&bull; <strong data-start="1487" data-end="1511">AC signal monitoring</strong> for pushbuttons, selector switches, and limit switches</p>
<p data-start="1570" data-end="1629">&bull; <strong data-start="1572" data-end="1601">Industrial control panels</strong> using SLC 500 PLC systems</p>
<p data-start="1631" data-end="1707">&bull; <strong data-start="1633" data-end="1663">Machine automation systems</strong> requiring high-voltage AC input detection</p>
<p data-start="1709" data-end="1785">&bull; <strong data-start="1711" data-end="1743">Process control environments</strong> with standardized 120V AC field signals</p>
<p data-start="1787" data-end="1859">&bull; <strong data-start="1789" data-end="1817">Discrete status feedback</strong> for interlocks and safety-related logic</p>
<p data-start="1861" data-end="1941">&bull; <strong data-start="1863" data-end="1893">Factory automation systems</strong> requiring stable and noise-tolerant AC inputs</p>
<hr data-start="1943" data-end="1946">
<h3 data-start="1947" data-end="1961">Advantages</h3>
<p data-start="1963" data-end="2039">&bull; <strong data-start="1965" data-end="1988">Wide AC input range</strong>, supporting standard industrial control voltages</p>
<p data-start="2041" data-end="2115">&bull; <strong data-start="2043" data-end="2071">16-channel input density</strong>, reducing overall rack space requirements</p>
<p data-start="2117" data-end="2198">&bull; <strong data-start="2119" data-end="2148">Robust AC input circuitry</strong>, improving noise immunity in harsh environments</p>
<p data-start="2200" data-end="2272">&bull; <strong data-start="2202" data-end="2234">Direct SLC 500 compatibility</strong>, ensuring simple system integration</p>
<p data-start="2274" data-end="2363">&bull; <strong data-start="2276" data-end="2305">Open-style chassis design</strong>, enabling secure mechanical and electrical installation</p>
<p data-start="2365" data-end="2468">&bull; <strong data-start="2367" data-end="2405">Industrial-grade thermal tolerance</strong>, supporting reliable operation across temperature variations</p>
</body></html>
<p><a href="https://www.excellentplc.com/allen-bradley-1746-1a16-digital-input-module/">Allen Bradley 1746-1A16 SLC 500 AC Digital Input Module</a>最先出现在<a href="https://www.excellentplc.com">Excellent PLC</a>。</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
