Company Information | ||||||||
[email protected] | ||||||||
Mobile | +8613666033393 | |||||||
+8613666033393 | ||||||||
13666033393 | ||||||||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
Product Introduction
The Triconex 4000058-110 Cable Assembly is a high-quality industrial cable designed specifically for Triconex safety and control systems. This assembly ensures reliable communication and power transfer between key system components in mission-critical automation environments. Manufactured with precision and built to endure harsh industrial conditions, it supports the stringent demands of process safety and control applications.
This cable assembly is engineered to provide low electrical resistance and robust shielding to minimize interference and signal degradation. It is widely used in sectors such as oil & gas, chemical processing, power generation, and other heavy industries where system integrity and safety are essential.
Product Parameters
Parameter | Description |
---|---|
Manufacturer | Triconex (Schneider Electric) |
Model | 4000058-110 |
Product Type | Cable Assembly |
Primary Function | System interconnection within Triconex systems |
Connector Type | Pre-installed industrial-grade connectors |
Shielding Type | Multi-layer EMI/RFI shielding |
Insulation Material | Industrial-grade polymer insulation |
Operating Temperature | -20°C to +70°C |
Conductor Material | High-purity copper conductors |
Electrical Resistance | Low-resistance for stable signal transmission |
Compliance Standards | CE, RoHS, IEC safety standards |
Cable Length | 10 feet |
Weight | 1.36 kg |
Product Applications
The 4000058-110 Cable Assembly is suitable for numerous industrial applications, including:
-
Safety Instrumented Systems (SIS): Facilitates connection between logic solvers and input/output modules.
-
Process Automation: Ensures secure signal transmission in complex control loops.
-
Power Plants: Used for communication and control wiring in turbine and generator systems.
-
Refineries and Petrochemical Plants: Supports critical process monitoring and control networks.
-
Redundant System Architectures: Compatible with triple modular redundancy (TMR) systems for fault tolerance.
-
Harsh Industrial Environments: Designed to withstand EMI, vibrations, and chemical exposure.
Product Advantages
-
Reliable Signal Integrity: Maintains clear, uninterrupted signal transmission with minimal noise.
-
Robust Construction: Built to endure mechanical stress, vibrations, and exposure to industrial contaminants.
-
Effective Shielding: Multi-layer EMI/RFI protection safeguards against electromagnetic interference.
-
Plug-and-Play Ready: Comes with pre-installed connectors for easy integration with Triconex hardware.
-
Regulatory Compliance: Adheres to international safety and environmental standards, ensuring system compliance.
-
Low Maintenance: Durable materials reduce the need for frequent replacements or repairs.
FAQ
1. What type of connectors does the 4000058-110 Cable Assembly use?
It features factory-installed, industrial-grade connectors compatible with Triconex systems.
2. Is the cable suitable for high-noise industrial environments?
Yes, it includes multi-layer shielding to minimize EMI and RFI interference.
3. Can this cable assembly be used in TMR (triple modular redundancy) configurations?
Yes, it is fully compatible with TMR system architectures.
4. What materials are used for the conductor and insulation?
High-purity copper conductors and industrial-grade polymer insulation are used.
5. Does this cable assembly comply with international safety standards?
Yes, it meets CE, RoHS, and IEC safety compliance standards.
6. How does the cable maintain signal integrity over long distances?
Through low electrical resistance conductors and precise impedance control.
7. Is the cable resistant to industrial chemicals and oils?
Yes, the insulation material provides strong resistance to oils and chemical exposure.
8. What temperature range can the cable reliably operate within?
Between -20°C and +70°C.
9. How does the cable assembly help prevent signal degradation?
By utilizing effective shielding and quality conductor materials to minimize interference and loss.
10. Is this cable assembly suitable for continuous vibration environments?
Yes, its robust construction is designed to withstand vibration and mechanical stress.
Recommended Related Models (Same Series or Function)
Model | Description |
---|---|
4000058-100 | Standard industrial cable assembly |
4000058-120 | Enhanced EMI-shielded cable assembly |
4000058-130 | Heavy-duty cable assembly for rugged environments |
4000058-140 | Multi-signal cable assembly |
4000058-150 | Quick-connect cable assembly |
4000058-160 | Flexible cable assembly for dynamic routing |
Popular Triconex Models (Same Brand)
Model | Description |
---|---|
3503E | Main Processor Module |
3625 | Analog Input Module |
3703E | Digital Input Module |
3805E | Digital Output Module |
4211 | Analog Output Module |
4351B | Communication Interface Module |