Product Introduction
The Triconex 4000103-520 Cable Assembly is a precision-engineered industrial connection solution designed to interface Triconex system modules with external devices in safety and process control applications. Manufactured to meet the high demands of critical process industries, this cable assembly ensures signal integrity, mechanical durability, and long-term operational reliability.
Built with high-grade copper conductors, advanced EMI/RFI shielding, and robust industrial connectors, the 4000103-520 delivers stable signal transmission under challenging environmental and electrical conditions. Its pre-terminated design simplifies installation, reduces field wiring errors, and helps achieve optimal performance in both digital and analog communication lines.
This model is widely adopted in safety instrumented systems (SIS), distributed control systems (DCS), and emergency shutdown systems (ESD), particularly in the oil & gas, petrochemical, and power generation sectors.
Product Parameters
Parameter | Specification |
---|---|
Product Name | Cable Assembly |
Model Number | 4000103-520 |
Brand | Triconex |
Function | Signal and power transmission between control modules and field devices |
Cable Type | Multi-core, shielded |
Conductor Material | High-purity copper |
Insulation Material | High-temperature, flame-retardant PVC/XLPE |
Shielding | Braided copper EMI/RFI shield |
Connector Type | Industrial-grade, pre-terminated |
Voltage Rating | 300V |
Signal Types Supported | Analog and digital |
Operating Temperature | -20°C to +80°C |
Dimensions | Approx. 25 mm diameter, length as specified |
Weight | Approx. 1.9 kg (varies by length) |
Compliance | IEC, UL, CE certified |
Typical Use | SIS, ESD, DCS connections |
Environmental Resistance | Vibration, moisture, and corrosion resistant |
Product Applications
-
Safety Instrumented Systems (SIS) – Transfers safety-critical output signals from controllers to actuators or alarm devices.
-
Distributed Control Systems (DCS) – Provides reliable communication between process control modules and field devices.
-
Emergency Shutdown Systems (ESD) – Connects shutdown logic to field hardware for rapid, reliable action during process upsets.
-
Power Generation – Interfaces with turbine controllers, circuit breakers, and monitoring systems.
-
Oil & Gas Production – Links control panels to emergency valves, compressors, and monitoring systems.
-
Chemical & Petrochemical – Supports accurate signal transfer for hazardous process control.
Product Advantages
-
Superior Signal Integrity – Advanced EMI/RFI shielding minimizes noise and ensures data accuracy.
-
High Reliability – Industrial-grade materials withstand vibration, moisture, and temperature fluctuations.
-
Ease of Installation – Pre-terminated design reduces wiring errors and shortens commissioning time.
-
Wide Compatibility – Designed for use with multiple Triconex system modules.
-
Low Maintenance – Long service life reduces downtime and servicing needs.
-
Standards Compliance – Meets or exceeds IEC, UL, and CE requirements for industrial safety and performance.
FAQ
-
Can the 4000103-520 transmit both analog and digital signals?
Yes, it supports both analog and digital communication without signal degradation. -
What type of shielding is used?
It uses a braided copper EMI/RFI shield for optimal noise suppression. -
Is it suitable for installation in hazardous areas?
Yes, when paired with certified Triconex equipment and proper installation practices. -
What is the maximum supported voltage?
The cable is rated for a maximum of 300V. -
Is the cable assembly compatible with all Triconex modules?
It is compatible with most Triconex I/O and controller modules, but model-specific confirmation is recommended. -
Does it require grounding?
Yes, proper shield grounding at one end is recommended to prevent ground loops. -
Can it be used outdoors?
It can be used outdoors if properly routed in protective conduit or tray with environmental protection. -
What is the recommended bending radius?
Typically, at least 10 times the cable diameter to maintain internal conductor integrity. -
Is the cable resistant to vibration?
Yes, it is built to handle high-vibration environments common in industrial settings. -
Can custom lengths be ordered?
Yes, custom lengths are available upon request to match installation needs.
Related Models (Same Series/Category)
Model | Description | Cable Type | Voltage Rating | Weight |
---|---|---|---|---|
4000103-530 | Extended length cable assembly | Shielded multi-core | 300V | 2.0 kg |
4000103-540 | High-flexibility version | Flexible shielded | 300V | 1.95 kg |
4000103-550 | Outdoor-rated version | UV-resistant shielded | 300V | 2.2 kg |
4000103-560 | Explosion-proof rated | Hazardous area shielded | 300V | 2.3 kg |
4000103-570 | Heavy-duty industrial version | Reinforced insulation | 300V | 2.1 kg |
4000103-580 | Lightweight version | Shielded twisted pair | 300V | 1.8 kg |
Popular Models from Triconex
Model | Description | Function | Dimensions | Weight |
---|---|---|---|---|
3721 | Digital input module | High-speed input processing | 260×40×200 mm | 0.8 kg |
3625 | Digital output module | Relay-based output switching | 260×40×200 mm | 0.9 kg |
3503E | Main processor module | System logic processing | 260×40×200 mm | 0.85 kg |
3118 | Analog input module | High-resolution signal acquisition | 260×40×200 mm | 0.82 kg |
8312 | Communication module | Network interface | 260×40×200 mm | 0.88 kg |
4351B | Analog output module | Precision signal output | 260×40×200 mm | 0.84 kg |