Product Introduction
The Yokogawa AAI841-H00/K4A00 Analog I/O Module is a critical component designed for industrial automation systems, specifically for use in distributed control systems (DCS). This module serves as a bridge between field analog signals and the control system, converting physical measurements like voltage and current into digital signals for processing, and vice versa. It supports multiple channels of analog input and output, providing versatility and precision necessary for complex process monitoring and control.
Known for its reliability and precision, the AAI841-H00/K4A00 is suitable for harsh industrial environments, maintaining stable operation under electrical noise, temperature fluctuations, and humidity. Its compact design allows easy integration into Yokogawa’s CENTUM series or other compatible control platforms. The module’s capability to handle various analog signal types makes it adaptable for a wide range of industrial applications.
Product Specifications
Parameter | Specification |
---|---|
Model Number | AAI841-H00/K4A00 |
Module Type | Analog Input/Output Module |
Number of Channels | 4 channels (analog input/output) |
Input Signal Range | ±10 V, 0-20 mA, 4-20 mA selectable |
Output Signal Range | 0-20 mA, 4-20 mA |
Resolution | 16-bit A/D and D/A conversion |
Accuracy | ±0.1% of full scale typical |
Response Time | Less than 100 ms |
Power Supply | 24 V DC nominal |
Communication Interface | Compatible with Yokogawa DCS bus |
Operating Temperature | -10°C to +60°C |
Storage Temperature | -25°C to +70°C |
Relative Humidity | 5% to 95% (non-condensing) |
Isolation | Channel-to-channel and channel-to-ground isolation |
Dimensions (WxHxD) | 107.5 × 32.8 × 130 mm |
Weight | 0.3 kg |
Mounting | DIN rail or rack mount |
Applications
The AAI841-H00/K4A00 is widely used in industries requiring precise process control and monitoring, such as:
-
Chemical and petrochemical processing plants for monitoring pressure, temperature, and flow
-
Power generation facilities to control various analog signals within turbines and boilers
-
Water and wastewater treatment plants for controlling pumps and valves
-
Oil and gas industry for refining processes and pipeline monitoring
-
Food and beverage manufacturing ensuring process consistency and safety
-
Pharmaceutical industry for strict process monitoring and control
Advantages
-
High Precision Measurement: With 16-bit resolution and low measurement error, it ensures accurate data conversion essential for reliable control.
-
Robust and Reliable: Designed to tolerate industrial conditions including temperature variations and electrical noise interference.
-
Versatile Signal Compatibility: Accepts and outputs a variety of analog signals, supporting many sensor and actuator types.
-
Fast Response Time: Rapid signal processing supports dynamic process control applications.
-
Electrical Isolation: Individual channel isolation protects signal integrity and prevents interference.
-
Compact and Flexible: Small form factor allows installation in tight control cabinets with options for DIN rail or rack mounting.
-
Seamless Integration: Fully compatible with Yokogawa’s DCS systems, enabling easy system configuration and maintenance.
Frequently Asked Questions (FAQ)
-
What analog input signal ranges does the module support?
The module supports ±10 V voltage input, 0-20 mA, and 4-20 mA current inputs, selectable based on application requirements. -
Can the output signals be configured for different ranges?
Yes, output can be set to either 0-20 mA or 4-20 mA according to the actuator or controller interface. -
What is the resolution and accuracy of the signal conversion?
The device features 16-bit resolution with a typical accuracy of ±0.1% of full scale. -
Does the module provide isolation between channels?
Yes, each channel is electrically isolated from others and from the module chassis ground to minimize noise and interference. -
What is the signal conversion response time?
The module typically responds within 100 milliseconds or less. -
What type of power supply is required?
A stable 24 V DC power source is required for module operation. -
Is the module suitable for harsh industrial environments?
Yes, it operates reliably in temperatures from -10°C to +60°C and relative humidity up to 95% non-condensing. -
Which communication protocols are supported?
It integrates with Yokogawa’s proprietary DCS communication bus systems. -
Can this module handle simultaneous analog input and output?
Yes, the module is designed to manage multiple channels of input and output simultaneously. -
What maintenance steps are necessary to keep the module functioning correctly?
Routine cleaning of connection terminals, periodic calibration checks, and verification of signal integrity are recommended.
Related Models (Same Series or Similar Functionality)
Model Number | Description | Channels | Signal Type | Key Feature |
---|---|---|---|---|
AAI840-H00/K4A00 | Analog Input Module | 4 | Voltage/Current Input | Input only module |
AAI842-H00/K4A00 | Analog Output Module | 4 | Current Output | Output only module |
AAI843-H00/K4A00 | Analog Input/Output Combination | 8 | Mixed I/O | Higher channel count |
AAI841-H01/K4A00 | Enhanced Analog I/O Module | 4 | Improved Accuracy | Extended temperature range |
AAI845-H00/K4A00 | High-Speed Analog Input Module | 4 | Fast response | Suitable for dynamic processes |
AAI846-H00/K4A00 | Redundant Analog Output Module | 4 | Redundant output | Increased reliability |
Popular Yokogawa Models (Same Brand)
Model Number | Description | Application | Key Feature |
---|---|---|---|
AAI831-H00/K4A00 | Temperature Input Module | Temperature sensing | Supports thermocouples |
AAI832-H00/K4A00 | Analog Input Module | General analog input | High accuracy |
AAI833-H00/K4A00 | Analog Output Module | Control valve output | 4-20 mA output |
AAI834-H00/K4A00 | Digital Input Module | Discrete signals | High-speed operation |
AAI835-H00/K4A00 | Digital Output Module | Relay control | Electrical isolation |
AAI837-H00/K4A00 | Universal Input Module | Multi-sensor input | Flexible configuration |