Yokogawa AAV141-S00 S2 Analog Input Modules Excellent PLC Co.,Ltd

PLC and DCS professional supplier

Yokogawa AAV141-S00 S2 Analog Input Modules

Manufacturer:Yokogawa

Product Number:AAV141-S00 S2

Product Type:Analog Input Modules

Origin:Japan

Dimensions:32.8 × 130 × 107.5 mm

Weight:0.2kg

Views:393

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24


New In Stock Original 100% New Unbelievable Prices! Fast Shipping! 30-Day Returns! 12-Month Warranty Trusted supplier Over 100,000 Automation Parts Available! 100% Original and Brand New !
  • Product Details
  • FAQs
  • Related
  • Contact Us
  • Packing & Delivery
  • Product Ratings

Yokogawa AAV141-S00 S2 Analog Input Modules

Product Overview

The Yokogawa AAV141-S00 S2 Analog Input Module is a precision module designed to interface with analog field signals in Yokogawa’s control systems. It supports high accuracy acquisition of process variables such as temperature, pressure, flow, and level by converting analog inputs into digital signals for processing and control.

This module is part of Yokogawa’s renowned DCS (Distributed Control System) family, providing reliable and stable analog input performance. It ensures tight integration with the control system, supports various sensor types, and offers flexible input configuration, making it ideal for complex industrial automation and process control environments.


Technical Specifications

Parameter Specification
Model Number AAV141-S00 S2
Module Type Analog Input Module
Input Channels 16 channels
Input Signal Types Current (4-20 mA), Voltage (0-10 V), Resistance, Thermocouple (varies by model/configuration)
Input Range Configurable per channel
Accuracy ±0.1% of full scale (typical)
Resolution 16-bit ADC
Response Time Typically 20 ms
Operating Voltage 24 V DC
Power Consumption Approximately 5 W
Operating Temperature 0°C to 55°C
Storage Temperature -20°C to 70°C
Humidity Range 10% to 90% non-condensing
Dimensions 32.8 × 130 × 107.5 mm
Weight 0.2 kg
Communication Interface Yokogawa S2 bus
Mounting Rack-mounted in Yokogawa control system racks
Safety Certifications Complies with relevant industrial standards

Applications

  • Process variable monitoring in industrial automation

  • Temperature, pressure, flow, and level signal acquisition

  • Integration into Yokogawa’s Centum and other DCS systems

  • Chemical, petrochemical, power generation, and water treatment plants

  • Facilities requiring precise and reliable analog input measurement


Advantages

  • High Accuracy and Stability: Ensures precise signal acquisition and minimal drift over time.

  • Multi-Channel Input: 16 channels allow simultaneous monitoring of multiple process variables.

  • Flexible Signal Support: Compatible with various sensor types and input signal ranges.

  • Easy Integration: Designed to seamlessly fit into Yokogawa’s control system architecture.

  • Robust Design: Industrial-grade components provide reliability under harsh conditions.

  • Simplified Configuration: Supports flexible channel configuration for diverse application needs.

  • Diagnostic Features: Built-in diagnostics for quick fault detection and maintenance.


Frequently Asked Questions (FAQ)

  1. How many input channels does the AAV141-S00 support?
    It supports 16 analog input channels.

  2. What types of input signals are supported?
    Current (4-20 mA), voltage (0-10 V), resistance, and thermocouple inputs depending on configuration.

  3. What is the accuracy of the module?
    Typical accuracy is ±0.1% of full scale.

  4. What is the operating temperature range?
    The module operates between 0°C and 55°C.

  5. Is this module compatible with Yokogawa’s DCS systems?
    Yes, it is designed for integration with Yokogawa’s Centum and other S2 bus systems.

  6. What communication interface does the module use?
    It uses the proprietary Yokogawa S2 bus communication protocol.

  7. What is the response time of the analog input?
    Approximately 20 milliseconds per channel.

  8. How is the module mounted?
    It is rack-mounted within Yokogawa control system racks.

  9. Does the module include diagnostic capabilities?
    Yes, it includes built-in diagnostics to aid maintenance.

  10. What power supply voltage does the module require?
    It requires a 24 V DC power supply.


Related Models

Model Number Description
AAV141-S01 S2 Analog Input Module (Enhanced version)
AAV142-S00 S2 Analog Output Module
AAV143-S00 S2 Digital Input Module
AAV144-S00 S2 Digital Output Module
AAV151-S00 S2 High-Precision Analog Input Module
AAV152-S00 S2 Thermocouple Input Module

Popular Yokogawa Models

Model Number Description
CENTUM VP Controller Yokogawa Distributed Control System Controller
AAV141-S00 S2 Analog Input Module
AAV142-S00 S2 Analog Output Module
YTA610 Temperature Transmitter Field temperature transmitter
YSC210 Flow Sensor Industrial flow sensor
YPV100 Pressure Transmitter Industrial pressure transmitter

Frequently Asked Questions (FAQ)

  1. How many input channels does the AAV141-S00 support?
    It supports 16 analog input channels.

  2. What types of input signals are supported?
    Current (4-20 mA), voltage (0-10 V), resistance, and thermocouple inputs depending on configuration.

  3. What is the accuracy of the module?
    Typical accuracy is ±0.1% of full scale.

  4. What is the operating temperature range?
    The module operates between 0°C and 55°C.

  5. Is this module compatible with Yokogawa’s DCS systems?
    Yes, it is designed for integration with Yokogawa’s Centum and other S2 bus systems.

  6. What communication interface does the module use?
    It uses the proprietary Yokogawa S2 bus communication protocol.

  7. What is the response time of the analog input?
    Approximately 20 milliseconds per channel.

  8. How is the module mounted?
    It is rack-mounted within Yokogawa control system racks.

  9. Does the module include diagnostic capabilities?
    Yes, it includes built-in diagnostics to aid maintenance.

  10. What power supply voltage does the module require?
    It requires a 24 V DC power supply.

Related Models

Model Number Description
AAV141-S01 S2 Analog Input Module (Enhanced version)
AAV142-S00 S2 Analog Output Module
AAV143-S00 S2 Digital Input Module
AAV144-S00 S2 Digital Output Module
AAV151-S00 S2 High-Precision Analog Input Module
AAV152-S00 S2 Thermocouple Input Module

Popular Yokogawa Models

Model Number Description
CENTUM VP Controller Yokogawa Distributed Control System Controller
AAV141-S00 S2 Analog Input Module
AAV142-S00 S2 Analog Output Module
YTA610 Temperature Transmitter Field temperature transmitter
YSC210 Flow Sensor Industrial flow sensor
YPV100 Pressure Transmitter Industrial pressure transmitter

Yokogawa AAV141-S00 S2 Analog Input Modules

Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.

As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.

Click to rate this post!
[Total: 0 Average: 0]

Prev:

Next:

Leave a message