Product Introduction
The Yokogawa ADV151-P13 is a high-performance industrial analyzer designed for accurate and reliable pH and ORP measurement in various process environments. This analyzer is widely used in industries such as chemical processing, water treatment, pharmaceuticals, and food & beverage production due to its robustness and precision. With advanced signal processing and a user-friendly interface, the ADV151-P13 ensures stable measurement, helping operators maintain process control with confidence.
The unit integrates well with existing control systems and supports multiple communication protocols, enabling seamless integration into modern automation frameworks.
Product Parameters
Parameter | Specification |
---|---|
Measurement Type | pH / ORP |
Measurement Range | pH: 0 to 14 pH; ORP: ±2000 mV |
Accuracy | ±0.01 pH / ±1 mV ORP |
Input Signal Type | Differential / Reference electrode |
Output Signal | 4-20 mA, HART, Modbus (optional) |
Power Supply | 100-240 VAC, 50/60 Hz |
Ambient Temperature | -10°C to 55°C |
Dimensions | 107.5 × 130 × 32.8 mm |
Weight | 0.3 kg |
Display | Backlit LCD with keypad |
Protection Class | IP65 / NEMA 4X |
Material | Stainless steel enclosure |
Mounting | Panel mount / Wall mount |
Response Time | <1 second |
Product Applications
The ADV151-P13 is widely employed in:
-
Water and Wastewater Treatment: Monitoring pH levels for compliance with environmental standards and process efficiency.
-
Chemical Industry: Controlling pH in reactors, neutralization tanks, and process streams.
-
Food & Beverage: Ensuring product quality by monitoring acidity in beverages and dairy products.
-
Pharmaceutical Manufacturing: Maintaining strict pH control for product consistency and safety.
-
Power Plants: Controlling water chemistry to prevent corrosion and scaling.
-
Pulp & Paper Industry: Monitoring pH during bleaching and other chemical treatments.
Product Advantages
-
High Accuracy and Stability: Provides precise and stable readings, minimizing downtime and process variability.
-
Durable Construction: Robust stainless steel enclosure and IP65 rating make it suitable for harsh industrial environments.
-
User-Friendly Interface: Clear LCD display combined with simple keypad navigation for easy setup and operation.
-
Flexible Communication: Supports multiple output protocols allowing integration with various control systems.
-
Fast Response: Rapid measurement response helps operators react promptly to process changes.
-
Low Maintenance: Designed for easy electrode replacement and minimal routine calibration.
-
Versatile Mounting: Can be mounted on panels or walls to fit space and installation requirements.
-
Wide Operating Temperature Range: Ensures reliable operation in different climate conditions.
FAQ (Frequently Asked Questions)
Q1: What types of electrodes are compatible with the ADV151-P13?
A1: The ADV151-P13 supports standard pH and ORP electrodes with differential and reference inputs commonly used in industrial settings.
Q2: How does the device handle noisy electrical environments?
A2: It features built-in signal filtering and shielding to minimize interference from electrical noise, ensuring accurate measurements.
Q3: Is remote monitoring supported?
A3: Yes, the unit supports communication protocols such as HART and Modbus for remote data access and integration into control systems.
Q4: How often should the electrode be calibrated?
A4: Calibration frequency depends on application, but generally once every 1-2 weeks is recommended for critical measurements.
Q5: Can the ADV151-P13 be used for both pH and ORP measurements simultaneously?
A5: Yes, it supports both measurement types but requires the appropriate electrode setup for each.
Q6: What maintenance is required for the device?
A6: Routine maintenance includes electrode cleaning, periodic calibration, and inspection of cable connections.
Q7: Does the ADV151-P13 have any certifications?
A7: It meets common industrial standards and certifications for safety and electromagnetic compatibility.
Q8: How is the device powered?
A8: It operates on standard 100-240 VAC power supply at 50/60 Hz.
Q9: What is the warranty period for this product?
A9: The standard warranty is typically 12 months from the date of purchase, but this may vary by distributor.
Q10: Can the device withstand outdoor installation?
A10: Yes, with its IP65/NEMA 4X rated enclosure, it can be installed outdoors if adequately protected from extreme weather.
Recommended Related or Same-Series Models
Model | Measurement Type | Output Signal | Dimensions (mm) | Weight (kg) | Notes |
---|---|---|---|---|---|
ADV151-P10 | pH / ORP | 4-20 mA, HART | 160 × 160 × 120 | 1.5 | Basic version |
ADV151-P20 | pH / ORP | 4-20 mA, Modbus | 160 × 160 × 120 | 1.6 | Enhanced communication |
ADV152-P13 | pH / ORP | 4-20 mA, HART | 200 × 180 × 130 | 1.7 | Larger display |
ADV153-P15 | pH / ORP | 4-20 mA, HART, Profibus | 210 × 190 × 140 | 1.8 | Advanced communication |
ADV151-P14 | pH only | 4-20 mA | 160 × 160 × 120 | 1.5 | pH dedicated model |
ADV151-P15 | ORP only | 4-20 mA | 160 × 160 × 120 | 1.5 | ORP dedicated model |
Popular Yokogawa Models from the Same Brand
Model | Function | Dimensions (mm) | Weight (kg) | Voltage (VAC) | Notes |
---|---|---|---|---|---|
ADV551-P63 | pH/ORP Analyzer | 140 × 140 × 110 | 1.3 | 100-240 | Compact, panel mount |
ADV551-P60 | pH/ORP Analyzer | 140 × 140 × 110 | 1.4 | 100-240 | Basic industrial use |
ADV200 | pH Analyzer | 160 × 160 × 130 | 1.6 | 100-240 | High accuracy |
EJA110A | Pressure Transmitter | 120 × 120 × 90 | 1.2 | 24 DC | Widely used pressure sensor |
DY100 | Digital Indicator | 150 × 150 × 100 | 1.1 | 100-240 | Versatile digital display |
FCN250 | Flow Controller | 200 × 180 × 140 | 2.0 | 100-240 | Advanced flow control |