Product Introduction
The Yokogawa ALP111 Communication Module is a high-performance communication interface designed to connect control systems to remote I/O networks via PROFIBUS-DP. It acts as a key communication bridge in distributed control environments, enabling seamless and deterministic data transfer between Yokogawa’s CENTUM VP or CENTUM CS 3000 systems and field devices that support the PROFIBUS-DP protocol.
The ALP111 enhances automation flexibility by integrating third-party field instruments, valves, actuators, and sensors into the centralized control environment. It is especially valuable in large-scale plants requiring interoperability, reduced wiring complexity, real-time control, and efficient maintenance strategies. As part of Yokogawa’s Field Control Station (FCS) communication architecture, it ensures high availability, diagnostics visibility, and excellent performance in mission-critical industrial applications.
Technical Specifications
Parameter | Details |
---|---|
Model | ALP111 |
Manufacturer | Yokogawa Electric Corporation |
Communication Protocol | PROFIBUS-DP (DP-V0 / DP-V1 compliant) |
Baud Rate | 9.6 kbps to 12 Mbps |
Max Devices per Channel | Up to 32 (without repeater) |
Number of Channels | 1 PROFIBUS-DP channel |
Power Supply | Supplied via the control system rack (24 VDC nominal) |
Interface Connector | D-sub 9-pin or terminal block (depending on system config) |
Functionality | Master communication with DP slaves (field devices) |
Redundancy Support | Yes (Hot standby module configuration supported) |
Configuration Tool | Yokogawa PRM / Engineering Tool / FDT/DTM integration |
Operating Temperature | 0°C to +50°C |
Storage Temperature | -20°C to +70°C |
Humidity Range | 5% to 95% RH (non-condensing) |
Mounting | Rack-mounted in Field Control Station |
Dimensions (H × W × D) | 130 x 129.5 x 32.8 mm |
Weight | 0.3 kg |
System Compatibility | CENTUM VP, CENTUM CS 3000 |
Compliance Standards | IEC 61158-2, PROFIBUS standard |
Applications
The ALP111 is widely applied across various industries that rely on PROFIBUS-DP for field communication. Common applications include:
-
Oil & Gas
Integration of PROFIBUS-compatible valve positioners and flow meters into the central DCS for precise process control. -
Chemical & Petrochemical
Interfacing multiple intelligent field devices in hazardous zones with full diagnostics and control access. -
Power Generation
Communication with field I/O, sensors, and actuator networks for turbine and boiler management. -
Pharmaceuticals
Enabling validated and traceable communications between DCS and manufacturing field equipment. -
Food & Beverage
Ensures fast, consistent, and synchronized control across production lines with PROFIBUS-DP compatibility. -
Water Treatment Plants
Offers seamless remote communication with distributed valve actuators and monitoring devices.
Key Advantages
-
Reliable PROFIBUS Master Functionality
As a PROFIBUS-DP master, the ALP111 effectively controls a network of intelligent field devices in real-time. -
High Interoperability
Enables integration of third-party PROFIBUS-DP devices into Yokogawa systems, enhancing flexibility. -
Diagnostics and Monitoring
Advanced diagnostic functions for quick fault detection and system status evaluation. -
Redundancy Ready
Supports module redundancy to improve system availability in critical applications. -
Space-Efficient Installation
Compact design fits into standard Yokogawa racks, reducing panel size and simplifying maintenance. -
Seamless Engineering Tool Integration
Easily configured using Yokogawa engineering tools or device-specific DTM software.
Frequently Asked Questions (FAQ)
-
What is the purpose of the ALP111 module?
It facilitates communication between Yokogawa control systems and field devices using the PROFIBUS-DP protocol. -
Can the ALP111 module control multiple PROFIBUS devices?
Yes, it can act as a master to control up to 32 devices directly per segment. -
Is the ALP111 suitable for redundant configurations?
Yes, it supports hot standby redundancy to ensure uninterrupted communication. -
Which systems are compatible with ALP111?
It is compatible with Yokogawa’s CENTUM VP and CENTUM CS 3000 control systems. -
Does the module support diagnostics?
Yes, it provides diagnostics on PROFIBUS communication status and device-level health. -
What is the communication speed supported?
It supports PROFIBUS speeds ranging from 9.6 kbps to 12 Mbps. -
How is the module powered?
It receives power from the control system rack (typically 24 VDC). -
Is the ALP111 compatible with non-Yokogawa field devices?
Yes, as long as they are PROFIBUS-DP compliant. -
What configuration tools are required?
Yokogawa Engineering Tools or PRM software, with optional FDT/DTM integration. -
Can it be mounted on a DIN rail?
No, it is designed for rack-mounting in a Yokogawa Field Control Station.
Related Models from the Same Series or Communication Family
Model | Description | Interface | System Compatibility |
---|---|---|---|
ALF111 | FOUNDATION Fieldbus communication module | FOUNDATION Fieldbus | CENTUM VP, CS 3000 |
ALE111 | Ethernet communication module | Ethernet TCP/IP | CENTUM VP, CS 3000 |
ALR121 | Redundant communication module for Vnet/IP | Vnet/IP | CENTUM VP |
AFV10D | Fast Ethernet communication module for safety system | Ethernet / Vnet/IP | ProSafe-RS |
ANB10D | Base Node Unit for FCS I/O slots | Backplane | CENTUM VP |
AIP827 | Analog input module for precise field data acquisition | Analog / Fieldbus | CENTUM VP |
Popular Yokogawa Modules (Same Brand)
Model | Function | Interface | System Compatibility |
---|---|---|---|
CP451 | Central Processing Unit | Internal Bus | CENTUM VP |
PW482 | Power Supply Module | Internal Rack Power | CENTUM VP |
NFCP100 | Compact Controller Unit | Ethernet / Vnet/IP | STARDOM |
AAR181-S00 | Analog Output Module | Field I/O | ProSafe-RS |
F3SP71-4N | CPU Module for safety controller | Safety Bus | ProSafe-RS |
S2PCU | Power Control Unit | Power Bus | CENTUM CS 3000 |