Product Introduction
The Yokogawa AMN21 Nest is a specialized mounting base (often referred to as a “nest”) designed specifically for accommodating Yokogawa relay-type I/O modules within the CENTUM VP and earlier CENTUM CS control system environments. As part of the system hardware infrastructure, the AMN21 serves a critical role in organizing, housing, and electrically interfacing the relay I/O modules such as the ARM or ARM11 series.
Engineered to ensure robustness and system integrity, the AMN21 offers reliable electrical contact and mechanical support while facilitating convenient module installation, removal, and maintenance. It is typically installed within system cabinets or panels and is compatible with field wiring terminals via designated terminal blocks.
Technical Specifications
| Parameter | Details |
|---|---|
| Model | AMN21 |
| Product Type | Nest/Base for Relay I/O Modules |
| Compatible Modules | ARM11, ARM10, ARO11, and other relay-type I/O modules from Yokogawa |
| Mounting Type | DIN Rail or Panel Mount |
| Number of Module Slots | 1 (accommodates one I/O module) |
| Terminal Type | Screw-type or terminal block (depending on system design) |
| Wiring Interface | Field signal wiring via backplane/terminal connectors |
| Power Distribution | Distributed via base (no independent power supply required) |
| Electrical Connection | Gold-plated contact interface |
| Operating Temperature | 0°C to 60°C |
| Storage Temperature | -20°C to 70°C |
| Humidity Range | 5% to 95% RH, non-condensing |
| Material | Flame-retardant resin body with metal reinforcement |
| Certifications | CE, RoHS, complies with Yokogawa reliability standards |
| Dimensions (W x H x D) | 125 x 130 x 248 mm |
| Weight | 2 kg |
Applications
The AMN21 is not a standalone functional module, but rather an integral part of Yokogawa’s modular automation hardware. Its main applications include:
-
Industrial Control Panels: Providing structured support for relay output modules in power distribution or interlocking systems.
-
Petrochemical and Refining Plants: Serving as the installation base for safety-critical relay output modules.
-
Power Generation Facilities: Housing relay modules used in turbine or generator trip circuits.
-
Manufacturing Automation: Assisting in the deployment of mechanical relays for actuators, motors, or alarm circuits.
-
Wastewater Treatment: Organizing I/O hardware used in motor control and alarm signaling.
Wherever relay-type outputs are required in control logic—particularly where galvanic isolation is essential—the AMN21 is part of the deployment strategy.
Product Advantages
-
Mechanical Stability: Rigid and flame-retardant design ensures long-term durability in harsh industrial environments.
-
Plug-and-Play Integration: Seamlessly integrates with Yokogawa relay modules, enabling quick deployment.
-
Secure Wiring: Designed with precise terminal layouts to prevent wiring errors and improve connection reliability.
-
Maintenance Friendly: Modules can be easily replaced or upgraded via the AMN21 without full cabinet disassembly.
-
Compact Form Factor: Supports high-density installations where space is a constraint.
-
Environmental Resilience: Operates reliably in wide temperature and humidity ranges.
-
Standardized Mounting: Supports both DIN rail and direct panel mounting for flexible installation.
Frequently Asked Questions (FAQ)
-
What is the function of the AMN21 in a Yokogawa control system?
It serves as the physical and electrical base for mounting Yokogawa relay output modules like ARM11. -
Which modules are compatible with the AMN21?
It supports ARM10, ARM11, ARO11, and similar relay-based I/O modules. -
Can the AMN21 be mounted on a DIN rail?
Yes, it supports both DIN rail and panel mounting configurations. -
Does the AMN21 include any active electronics?
No, it is a passive base that facilitates connectivity and mechanical support. -
Is it hot-swappable?
Modules mounted on the AMN21 can often be replaced during runtime if supported by the control system and safety protocol. -
What are the terminal connection types?
Terminal connection is typically via screw terminals or detachable terminal blocks. -
How durable is the AMN21 in extreme conditions?
It is designed for industrial use with a wide operating range of 0°C to 60°C and 5–95% humidity. -
Does the AMN21 include integrated fuses or surge protection?
No, those protections are handled by the connected modules or external systems. -
What materials are used in the AMN21 nest?
It is constructed from flame-retardant resin with internal metal reinforcements. -
Can I use AMN21 for analog modules?
No, it is specifically designed for relay-type output modules.
Recommended Related or Similar Models (Same Series or Function)
| Model | Description | Compatible Module Type | Mount Type | Notes |
|---|---|---|---|---|
| AMN11 | Nest for analog I/O modules | AAI, AAO | Panel/DIN rail | Analog module mounting |
| AMN31 | Nest for digital I/O modules | ADV, ADO | Panel | For high-speed discrete I/O |
| AMN24 | 4-channel relay module nest | ARM24 | Panel | Higher density relay module base |
| AMN26 | Nest for isolated digital input modules | AVW10 | DIN rail | For digital input safety signals |
| AMN13 | Multipurpose nest for mixed signal modules | Multiple | Panel | Flexible mounting support |
| AMN22 | Nest for relay output with signal isolation | ARM22 | Panel | Galvanic isolation for critical I/O |
Popular Yokogawa Models (Same Brand)
| Model | Description | Type | Application |
|---|---|---|---|
| AAI143-H50 | Analog Input Module (HART, 4–20 mA) | Analog Input | Smart sensor data acquisition |
| CP451-10 | Field Control Station CPU | Controller | Core CPU for CENTUM system |
| AAI543-H00 | Analog Input Module (non-HART) | Analog Input | Standard signal input |
| ADO141 | Digital Output Module | Digital Output | Discrete signal control |
| PW482 | Power Supply Module | Power Supply | Redundant system power |
| VJ72 | Terminal Block (32-point) | Wiring Accessory | Field signal interface |
Excellent PLC