Yokogawa EB401 ER Bus Interface Master Module Excellent PLC Co.,Ltd

PLC and DCS professional supplier

Yokogawa EB401 ER Bus Interface Master Module

Manufacturer:Yokogawa

Product Number:EB401

Product Type:ER Bus Interface Master Module

Origin:Japan

Dimensions:144.65 x 130 x 32.8 mm

Weight:0.3 kg

Views:215

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24


  • Product Details
  • FAQs
  • Related
  • Contact Us
  • Packing & Delivery
  • Product Ratings
Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Yokogawa EB401 ER Bus Interface Master Module

Product Introduction

The Yokogawa EB401 ER Bus Interface Master Module is a key component within Yokogawa’s distributed control systems (DCS). It serves as the master interface for the ER Bus communication network, enabling high-speed, reliable data exchange between system controllers and remote I/O modules.

Designed for mission-critical industrial applications, EB401 supports redundancy, fault detection, and self-diagnostics to ensure uninterrupted communication. Its robust design makes it suitable for harsh environments, commonly seen in industries like oil & gas, power generation, and petrochemicals.


Product Specifications

Parameter Description
Model EB401
Function ER Bus Interface Master Module
Communication Protocol ER Bus
Data Transfer Mode High-speed synchronous communication
Power Supply 24 V DC (nominal)
Power Consumption Approx. 6 W
Operating Temperature 0°C to +55°C
Storage Temperature -20°C to +70°C
Relative Humidity 5% to 95% RH (non-condensing)
Installation Method Rack-mounted within System Rack
Compliance CE, RoHS
Redundancy Support Yes
Diagnostic Features Self-diagnostic, Error Detection, LED Status
Dimensions (H × W × D) 144.65 x 130 x 32.8 mm
Weight 0.3 kg

Applications

  • Distributed Control Systems (DCS): Ensures real-time communication between control units and remote I/O.

  • Process Automation: Provides high-speed, reliable data exchange for complex industrial processes.

  • Redundant Safety Systems: Maintains continuous operation in safety-critical environments.

  • Power Generation Plants: Optimizes control and monitoring for energy production facilities.

  • Oil & Gas Operations: Guarantees data reliability for upstream and downstream processes.

  • Petrochemical Industry: Handles communication in hazardous process conditions.


Product Advantages

  • High-Speed Communication: Supports synchronous data exchange with minimal latency.

  • Redundancy Design: Dual-channel ER bus ensures uninterrupted operation.

  • Compact and Modular: Saves panel space and simplifies installation.

  • Wide Environmental Tolerance: Functions in extreme temperature and humidity conditions.

  • Field Upgradeable: Firmware can be updated without removing the module.

  • Certified Safety: Complies with CE and RoHS industrial standards.


FAQ

1. How does the EB401 ensure communication reliability in redundant setups?
It uses dual ER bus channels for automatic failover if one path fails.

2. Can EB401 handle high-speed real-time data?
Yes, it supports high-speed synchronous communication for real-time process control.

3. How many slave devices can EB401 manage?
It supports multiple ER bus slaves; the exact number depends on the system design.

4. Does EB401 allow online module replacement?
Yes, it supports hot-swapping without system shutdown.

5. What diagnostic features are included?
It offers self-diagnostics, error detection, and LED status indicators for quick fault isolation.

6. Is EB401 compatible with Yokogawa CENTUM VP?
Yes, it is fully integrated with CENTUM VP and other Yokogawa DCS platforms.

7. Can the firmware be updated in the field?
Yes, the module supports online firmware updates through Yokogawa tools.

8. How does EB401 resist electromagnetic interference?
It is EMI-shielded and complies with IEC standards for EMC protection.

9. What is the recommended power supply tolerance?
24 V DC ±10% is required for optimal performance.

10. How does EB401 handle communication errors?
It uses error detection and correction protocols to ensure data integrity.


Related Models (Same Series or Functionality)

Model Description
EB402 ER Bus Interface Slave Module
EB403 High-Speed ER Bus Master for Large Systems
EB301 ER Bus Expansion Interface
EB310 Redundant ER Bus Communication Module
ERB100 ER Bus Coupler for System Integration
EB420 ER Bus Extended Range Master Module

Popular Yokogawa Models

Model Description
AAI143-S00 16-Channel Analog Input Module
AAM50 Multi-Point Input Module for Field Devices
ADV151 16-Point Digital Output Module
CP451-10 High-Performance CPU Module for CENTUM VP
PW482-50 Redundant Power Supply Module
ATD5A-00 Temperature Input Module for DCS Systems

FAQ

1. How does the EB401 ensure communication reliability in redundant setups?
It uses dual ER bus channels for automatic failover if one path fails.

2. Can EB401 handle high-speed real-time data?
Yes, it supports high-speed synchronous communication for real-time process control.

3. How many slave devices can EB401 manage?
It supports multiple ER bus slaves; the exact number depends on the system design.

4. Does EB401 allow online module replacement?
Yes, it supports hot-swapping without system shutdown.

5. What diagnostic features are included?
It offers self-diagnostics, error detection, and LED status indicators for quick fault isolation.

6. Is EB401 compatible with Yokogawa CENTUM VP?
Yes, it is fully integrated with CENTUM VP and other Yokogawa DCS platforms.

7. Can the firmware be updated in the field?
Yes, the module supports online firmware updates through Yokogawa tools.

8. How does EB401 resist electromagnetic interference?
It is EMI-shielded and complies with IEC standards for EMC protection.

9. What is the recommended power supply tolerance?
24 V DC ±10% is required for optimal performance.

10. How does EB401 handle communication errors?
It uses error detection and correction protocols to ensure data integrity.

Related Models (Same Series or Functionality)

Model Description
EB402 ER Bus Interface Slave Module
EB403 High-Speed ER Bus Master for Large Systems
EB301 ER Bus Expansion Interface
EB310 Redundant ER Bus Communication Module
ERB100 ER Bus Coupler for System Integration
EB420 ER Bus Extended Range Master Module

Popular Yokogawa Models

Model Description
AAI143-S00 16-Channel Analog Input Module
AAM50 Multi-Point Input Module for Field Devices
ADV151 16-Point Digital Output Module
CP451-10 High-Performance CPU Module for CENTUM VP
PW482-50 Redundant Power Supply Module
ATD5A-00 Temperature Input Module for DCS Systems

Yokogawa EB401 ER Bus Interface Master Module

Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.

As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.

Click to rate this post!
[Total: 0 Average: 0]

Prev:

Next:

Leave a message