Yokogawa NFLR121-S50 S1 Serial Communication Module Excellent PLC Co.,Ltd

PLC and DCS professional supplier

Yokogawa NFLR121-S50 S1 Serial Communication Module

Manufacturer:Yokogawa

Product Number:NFLR121-S50 S1

Product Type:Serial Communication Module

Origin:Japan

Dimensions:130 x 142.9 x 32.8mm

Weight :0.3 kg

Views:227

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24


  • Product Details
  • FAQs
  • Related
  • Contact Us
  • Packing & Delivery
  • Product Ratings
Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Yokogawa NFLR121-S50 S1 Serial Communication Module

Product Introduction

The Yokogawa NFLR121-S50 S1 Serial Communication Module is a reliable interface module designed for industrial automation systems within the Yokogawa Node Field Control (NF) series. It provides seamless communication between controllers and external devices through standardized serial protocols. Built with a focus on performance, stability, and compatibility, this module supports efficient data exchange in demanding process control environments such as power generation, oil & gas, chemical processing, and large-scale manufacturing.


Technical Specifications

Parameter Description
Model Number NFLR121-S50 S1
Product Type Serial Communication Module
Error Detection CRC and parity check
Input Voltage 24 V DC (typical), with tolerance range ±10%
Power Consumption 4.5 W
Dimensions 130 x 142.9 x 32.8mm
Weight 0.3 kg
Mounting Type DIN rail or chassis-mounted
Operating Temperature Range 0°C to 55°C
Storage Temperature Range -20°C to 70°C
Humidity Range 10% to 90% RH (non-condensing)
Certification CE, RoHS compliant

Product Applications

  • Process Automation – Integration of controllers with legacy field devices.

  • Power Plants – Real-time communication between turbine controllers and monitoring systems.

  • Oil & Gas – Data transmission for remote sensors and instrumentation panels.

  • Chemical Industry – Interfacing analytical instruments with central DCS systems.

  • Manufacturing – Connection between PLCs and SCADA systems for production line monitoring.

  • Utilities – Remote communication with substations and distributed assets.


Product Advantages

  • High Compatibility: Supports multiple serial protocols, enabling integration with various third-party devices.

  • Stable Operation: Designed for continuous operation in industrial environments with built-in error detection.

  • Flexible Configuration: Customizable transmission settings to meet diverse application requirements.

  • Compact Design: Small footprint with lightweight construction for easy installation.

  • Energy Efficiency: Low power consumption without compromising communication reliability.

  • System Integration: Seamlessly connects to Yokogawa NF series and CENTUM systems.


FAQ

Q1: What serial protocols are supported by the NFLR121-S50 S1 module?
A1: The module supports RS-232C, RS-422/485, and selected proprietary protocols.

Q2: What is the maximum supported baud rate?
A2: The maximum configurable baud rate is 115.2 kbps.

Q3: Can the module handle multiple devices on RS-485?
A3: Yes, RS-485 supports multi-drop communication with proper termination.

Q4: Does the module support CRC-based error checking?
A4: Yes, CRC and parity error detection mechanisms are implemented.

Q5: Is the communication configuration software-adjustable?
A5: Yes, transmission speed, data bits, stop bits, and parity can be configured through system software.

Q6: Can the module operate in redundant control systems?
A6: Yes, it is compatible with redundant architectures for high availability.

Q7: Does it support hot-swapping during operation?
A7: Hot-swapping is not recommended; modules should be replaced during system maintenance.

Q8: What isolation protection does it provide between ports and system bus?
A8: The module offers galvanic isolation to protect against voltage fluctuations and noise.

Q9: How is data integrity maintained in noisy environments?
A9: Error detection, shielding, and isolation mechanisms ensure reliable transmission in harsh conditions.

Q10: Can this module be integrated with Yokogawa CENTUM VP systems?
A10: Yes, it is fully compatible with Yokogawa’s CENTUM VP DCS platforms.


Related Models

Model Number Description
NFLR111-S50 S1 Serial communication module with single port
NFLR131-S50 S1 Dual-channel serial communication module
NFCP102-S50 S1 Control processor module
NFIO211-S50 S1 Digital I/O module
NFAD121-S50 S1 Analog input module
NFAD141-S50 S1 Analog output module

Popular Yokogawa Models

Model Number Description
AAI143-S00 Analog input module
AAI841-S00 16-channel analog input module
ADV151-P00 Processor interface module
CP451-10 Control processor module
PW482-10 Power supply module
AMM32 Multiplexer module
AAR181-S00 Analog input module with HART support
ADM52 Digital communication module

FAQ

Q1: What serial protocols are supported by the NFLR121-S50 S1 module?
A1: The module supports RS-232C, RS-422/485, and selected proprietary protocols.

Q2: What is the maximum supported baud rate?
A2: The maximum configurable baud rate is 115.2 kbps.

Q3: Can the module handle multiple devices on RS-485?
A3: Yes, RS-485 supports multi-drop communication with proper termination.

Q4: Does the module support CRC-based error checking?
A4: Yes, CRC and parity error detection mechanisms are implemented.

Q5: Is the communication configuration software-adjustable?
A5: Yes, transmission speed, data bits, stop bits, and parity can be configured through system software.

Q6: Can the module operate in redundant control systems?
A6: Yes, it is compatible with redundant architectures for high availability.

Q7: Does it support hot-swapping during operation?
A7: Hot-swapping is not recommended; modules should be replaced during system maintenance.

Q8: What isolation protection does it provide between ports and system bus?
A8: The module offers galvanic isolation to protect against voltage fluctuations and noise.

Q9: How is data integrity maintained in noisy environments?
A9: Error detection, shielding, and isolation mechanisms ensure reliable transmission in harsh conditions.

Q10: Can this module be integrated with Yokogawa CENTUM VP systems?
A10: Yes, it is fully compatible with Yokogawa’s CENTUM VP DCS platforms.

Related Models

Model Number Description
NFLR111-S50 S1 Serial communication module with single port
NFLR131-S50 S1 Dual-channel serial communication module
NFCP102-S50 S1 Control processor module
NFIO211-S50 S1 Digital I/O module
NFAD121-S50 S1 Analog input module
NFAD141-S50 S1 Analog output module

Popular Yokogawa Models

Model Number Description
AAI143-S00 Analog input module
AAI841-S00 16-channel analog input module
ADV151-P00 Processor interface module
CP451-10 Control processor module
PW482-10 Power supply module
AMM32 Multiplexer module
AAR181-S00 Analog input module with HART support
ADM52 Digital communication module

Yokogawa NFLR121-S50 S1 Serial Communication Module

Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.

As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.

Click to rate this post!
[Total: 0 Average: 0]

Prev:

Next:

Leave a message