The Yokogawa SSC10S-F Safety Control Unit is a core component of Yokogawa’s safety instrumented system (SIS) designed for process industries that require high levels of operational safety and system reliability. As part of the ProSafe-RS platform, the SSC10S-F ensures continuous monitoring and control of safety-critical functions, protecting personnel, equipment, and the environment from hazardous events. It provides a robust hardware and software platform that integrates seamlessly with distributed control systems (DCS), ensuring unified plant safety and process automation management.
Product Specifications
Parameter | Specification |
---|---|
Model Number | SSC10S-F |
Product Type | Safety Control Unit (SIS module) |
System Platform | ProSafe-RS |
Input Channels | Digital and Analog (configurable) |
Output Channels | Digital and Analog (configurable) |
Safety Integrity Level (SIL) | SIL3 (IEC 61508 compliant) |
Processor Type | Redundant CPU with fault tolerance |
Communication Protocols | Vnet/IP, SafetyNet |
Power Supply | 24 V DC |
Operating Temperature | -10°C to 55°C |
Storage Temperature | -20°C to 70°C |
Humidity Tolerance | 5% to 95% RH (non-condensing) |
EMC Compliance | IEC/EN standards |
Dimensions | 482.6 x 266 x 88.1 mm |
Weight | 13 kg |
Certifications | CE, ATEX, IECEx, TÜV |
Applications
The SSC10S-F Safety Control Unit is utilized in various safety-critical industrial applications:
-
Oil & Gas Industry: Emergency shutdown systems (ESD), fire and gas systems (F&G), and high-integrity pressure protection systems (HIPPS).
-
Petrochemical Plants: Protecting against overpressure, toxic release, or fire incidents.
-
Power Generation: Turbine safety systems and boiler protection.
-
Chemical Industry: Process interlock management and hazardous reaction containment.
-
Water Treatment Plants: Critical fail-safe monitoring and control.
-
General Industrial Automation: Integration with Yokogawa’s DCS for unified plant safety and control.
Advantages
-
Certified Safety Compliance: Achieves SIL3 certification under IEC 61508 for maximum reliability.
-
High Availability: Redundant CPU architecture ensures continuous operation with fault tolerance.
-
Seamless Integration: Works directly with Yokogawa’s DCS platforms for unified process and safety control.
-
Scalability: Flexible configuration of input and output channels for different plant sizes.
-
Robust Communication: Uses Vnet/IP and SafetyNet for fast and reliable data transfer.
-
Environmental Resistance: Designed to withstand industrial temperature, humidity, and EMC conditions.
-
Reduced Downtime: Diagnostic functions allow early detection of faults and predictive maintenance.
-
Global Certifications: Certified for use in hazardous and regulated industries worldwide.
FAQ
-
What safety standard does the SSC10S-F comply with?
It complies with IEC 61508 and is certified up to Safety Integrity Level 3 (SIL3). -
Which communication protocols are supported?
It supports Vnet/IP and SafetyNet for seamless integration with Yokogawa systems. -
Can the SSC10S-F operate with redundant configurations?
Yes, it supports redundant CPU architecture for fault tolerance and continuous availability. -
What types of I/O channels are available in the SSC10S-F?
It supports both digital and analog input/output channels, configurable based on application needs. -
Is the SSC10S-F compatible with Yokogawa’s DCS platforms?
Yes, it integrates seamlessly with Yokogawa’s CENTUM VP and other control platforms. -
How does the SSC10S-F handle diagnostics?
It includes built-in diagnostic functions for detecting hardware, communication, and logic faults in real-time. -
What is the typical response time of the SSC10S-F?
It provides fast safety response times, ensuring quick execution of safety-critical actions. -
Does the SSC10S-F support hot-swapping?
Yes, modules can be replaced without shutting down the entire system, enhancing maintainability. -
What is the power supply requirement for the SSC10S-F?
It operates on a standard 24 V DC power supply. -
Can the SSC10S-F be used in hazardous locations?
Yes, it is certified by ATEX and IECEx for use in hazardous industrial environments.
Related Models (Same Series or Related)
Model Number | Type | Key Feature |
---|---|---|
SSC10D-F | Safety Control Unit | Dual redundant CPU design |
SSC20S-F | Safety Control Unit | Expanded I/O capacity |
SSC50S-F | Safety Controller | High-speed safety processing |
SSC60S-F | Safety Control Unit | Enhanced diagnostics functions |
SSC100S-F | Safety Control Unit | Large-scale plant safety system integration |
SSC200S-F | Safety Controller | Advanced redundancy and scalability |
Popular Models (Same Brand)
Model Number | Type | Key Feature |
---|---|---|
FIO110 | Field I/O Module | Flexible input/output expansion |
CP451-10 | Controller Module | High-performance control processor |
ALR121 | Alarm Module | Reliable alarm and alert handling |
PW482-10 | Power Supply Module | Stable 24 V DC power for Yokogawa systems |
AIP827-10 | Analog Input Module | High accuracy analog signal acquisition |
SAI143-H50 | Safety Analog Input Module | Certified SIL input for safety applications |