Emerson VE4017P0 KJ3242X1-BA2 Series 2 Fieldbus H1 Card Excellent PLC Co.,Ltd

PLC and DCS professional supplier

Emerson VE4017P0 KJ3242X1-BA2 Series 2 Fieldbus H1 Card

Manufacturer:Emerson

Product Number:VE4017P0 KJ3242X1-BA2

Product Type:Series 2 Fieldbus H1 Card

Origin:USA

Dimensions:107 x 41 x 105 mm

Weight:0.3 kg

Views:383

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24


New In Stock Original 100% New Unbelievable Prices! Fast Shipping! 30-Day Returns! 12-Month Warranty Trusted supplier Over 100,000 Automation Parts Available! 100% Original and Brand New !
  • Product Details
  • FAQs
  • Related
  • Contact Us
  • Packing & Delivery
  • Product Ratings

Emerson VE4017P0 KJ3242X1-BA2 Series 2 Fieldbus H1 Card

Product Description

The Emerson VE4017P0 KJ3242X1-BA2 is a Series 2 Fieldbus H1 Card designed for integration within the DeltaV™ system. It supports high-speed digital communication with field instruments using the FOUNDATION Fieldbus H1 protocol. The module is engineered for installation in hazardous areas and meets international safety standards, including ATEX and IECEx certifications.


Technical Specifications

Parameter Specification
Model Number VE4017P0 KJ3242X1-BA2
Series Series 2
Fieldbus Protocol FOUNDATION Fieldbus H1
Local Bus Power 12 VDC at 300 mA
Fieldbus Power 9–32 VDC at 12 mA per port
Operating Temperature -40°C to +70°C
Relative Humidity 5% to 95% non-condensing
Shock Resistance 10g, 11 msec (half sine wave)
Vibration 1mm P-P (2–13.2 Hz), 0.7g (13.2–150 Hz)
Contaminant Resistance ISA-S71.04 Class G3
Dimensions (H x W x D) 107 x 41 x 105 mm
Weight 0.3 kg

Applications

  • Integration of FOUNDATION Fieldbus H1 field devices

  • Hazardous industrial environments (Zone 2/Class I Div 2)

  • Process automation systems using DeltaV™ architecture

  • Oil & gas, chemical, and power generation facilities

  • Distributed control system expansions


Product Advantages

  • Certified for hazardous zones (ATEX, IECEx, FM)

  • Compact size, ideal for space-constrained systems

  • Supports robust digital fieldbus communications

  • Vibration and shock-resistant design

  • Maintenance-free, no calibration required

  • High environmental resistance (Class G3 contaminants)


FAQ

Q1: What is the main function of the KJ3242X1-BA2 Fieldbus H1 Card?
A1: It enables communication between the DeltaV system and field devices using the FOUNDATION Fieldbus H1 protocol.

Q2: Can this module be used in hazardous environments?
A2: Yes, it is certified for use in Zone 2/Class I Division 2 hazardous areas.

Q3: What is the required fieldbus power input?
A3: It operates with 9–32 VDC at 12 mA per port.

Q4: Is hot-swapping allowed for this module?
A4: No, power must be removed before inserting or removing the module.

Q5: What temperature range can it withstand?
A5: It supports a wide range from -40°C to +70°C.

Q6: Does it require periodic calibration?
A6: No, the unit is maintenance-free and does not require calibration.

Q7: How does it ensure correct installation?
A7: It uses a rotary keying system to match terminal blocks with the I/O card.

Q8: Can it resist harsh industrial contaminants?
A8: Yes, it is rated for ISA-S71.04 Class G3 airborne contaminants.

Q9: What are its vibration specifications?
A9: It can handle 1mm peak-to-peak from 2–13.2 Hz and 0.7g from 13.2–150 Hz.

Q10: Is it compatible with all DeltaV systems?
A10: It is designed for DeltaV M-Series systems with compatible terminal blocks.


Related Models (Same Series or Category)

Model Number Description Dimensions (mm) Weight (kg)
VE4018P0 KJ3221X1-BA1 Series 2 Fieldbus H1 Card, 2-channel 107 x 41 x 105 0.3
VE4012P0 KJ3001X1-BB1 Analog Input Card 107 x 41 x 105 0.3
VE4036P2 KJ3002X1-BG2 Analog Output Card 107 x 41 x 105 0.3
VE4002P2 KJ3204X1-BA1 Discrete Input Card 107 x 41 x 105 0.3
VE4003P2 KJ3205X1-BA1 Discrete Output Card 107 x 41 x 105 0.3
VE4001P2 KJ4001X1-BA2 Power Supply Module 107 x 41 x 105 0.3

Popular Emerson Models

Model Number Description Dimensions (mm) Weight (kg)
KJ3001X1-BB1 12 Channel Analog Input Module 107 x 41 x 105 0.3
KJ3002X1-BG2 8 Channel Analog Output Module 107 x 41 x 105 0.3
KJ3204X1-BA1 16 Channel Discrete Input Module 107 x 41 x 105 0.3
KJ3205X1-BA1 16 Channel Discrete Output Module 107 x 41 x 105 0.3
KJ3221X1-BA1 2-Channel Fieldbus H1 Card 107 x 41 x 105 0.3
KJ4001X1-BA2 DeltaV Power Supply 107 x 41 x 105 0.3

FAQ

Q1: What is the main function of the KJ3242X1-BA2 Fieldbus H1 Card?
A1: It enables communication between the DeltaV system and field devices using the FOUNDATION Fieldbus H1 protocol.

Q2: Can this module be used in hazardous environments?
A2: Yes, it is certified for use in Zone 2/Class I Division 2 hazardous areas.

Q3: What is the required fieldbus power input?
A3: It operates with 9–32 VDC at 12 mA per port.

Q4: Is hot-swapping allowed for this module?
A4: No, power must be removed before inserting or removing the module.

Q5: What temperature range can it withstand?
A5: It supports a wide range from -40°C to +70°C.

Q6: Does it require periodic calibration?
A6: No, the unit is maintenance-free and does not require calibration.

Q7: How does it ensure correct installation?
A7: It uses a rotary keying system to match terminal blocks with the I/O card.

Q8: Can it resist harsh industrial contaminants?
A8: Yes, it is rated for ISA-S71.04 Class G3 airborne contaminants.

Q9: What are its vibration specifications?
A9: It can handle 1mm peak-to-peak from 2–13.2 Hz and 0.7g from 13.2–150 Hz.

Q10: Is it compatible with all DeltaV systems?
A10: It is designed for DeltaV M-Series systems with compatible terminal blocks.

Related Models (Same Series or Category)

Model Number Description Dimensions (mm) Weight (kg)
VE4018P0 KJ3221X1-BA1 Series 2 Fieldbus H1 Card, 2-channel 107 x 41 x 105 0.3
VE4012P0 KJ3001X1-BB1 Analog Input Card 107 x 41 x 105 0.3
VE4036P2 KJ3002X1-BG2 Analog Output Card 107 x 41 x 105 0.3
VE4002P2 KJ3204X1-BA1 Discrete Input Card 107 x 41 x 105 0.3
VE4003P2 KJ3205X1-BA1 Discrete Output Card 107 x 41 x 105 0.3
VE4001P2 KJ4001X1-BA2 Power Supply Module 107 x 41 x 105 0.3

Popular Emerson Models

Model Number Description Dimensions (mm) Weight (kg)
KJ3001X1-BB1 12 Channel Analog Input Module 107 x 41 x 105 0.3
KJ3002X1-BG2 8 Channel Analog Output Module 107 x 41 x 105 0.3
KJ3204X1-BA1 16 Channel Discrete Input Module 107 x 41 x 105 0.3
KJ3205X1-BA1 16 Channel Discrete Output Module 107 x 41 x 105 0.3
KJ3221X1-BA1 2-Channel Fieldbus H1 Card 107 x 41 x 105 0.3
KJ4001X1-BA2 DeltaV Power Supply 107 x 41 x 105 0.3

Emerson VE4017P0 KJ3242X1-BA2 Series 2 Fieldbus H1 Card

Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.

As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.

Click to rate this post!
[Total: 0 Average: 0]

Prev:

Next:

Leave a message