| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666033393 | |||||||
| +8613666033393 | ||||||||
| 13666033393 | ||||||||
| Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Yokogawa SSB401-S53 Bus Interface Slave Module
- Product Details
- FAQs
- Related
- Contact Us
- Packing & Delivery
- Product Ratings

Product Introduction
The Yokogawa SSB401-S53 is an ESB Bus Interface Slave Module designed to bridge field devices and sensors with a central Distributed Control System (DCS) via Yokogawa’s Ethernet-based Standard Bus (ESB) protocol. Engineered for robust, high-precision communication, it ensures seamless integration into both new and existing Yokogawa automation installations.
Technical Parameters
| Parameter | Specification |
|---|---|
| Model | SSB401-S53 |
| Function | ESB Bus Interface Slave Module: connects field I/O and sensors to ESB network |
| Supported Protocols | Yokogawa ESB; PROFIBUS DP, DeviceNet, CANopen (depending on firmware) |
| Data Transfer Rate | Up to 10 Mbps |
| Input Signal Types | Voltage, current, thermocouples, RTDs, etc. |
| Input Range | ±30 mV/V |
| Output Signal | 4–20 mA or digital (model-dependent) |
| Accuracy | ±0.05 % of full scale |
| Frequency Response | DC to 100 kHz |
| Power Supply | 24 V DC |
| Operating Temperature | –10 °C to +60 °C |
| Dimensions | 130 x 142.5 x 32.8mm |
| Weight | 0.45 kg |
Applications
-
Integration of analog and digital field signals into Yokogawa DCS networks for process control and monitoring
-
Extension of safety-instrumented loops within ProSafe-RS or CENTUM systems via ESB
-
Data aggregation from remote I/O racks and substations in utilities, chemical plants, and oil & gas installations
Key Advantages
-
High Precision & Stability: ±0.05 % full-scale accuracy minimizes calibration drift and ensures repeatable readings.
-
Multi-Protocol Flexibility: Supports leading industrial networks (PROFIBUS DP, DeviceNet, CANopen) alongside proprietary ESB.
-
Compact & Robust: Small footprint (150 × 20 × 25 mm) and rugged –10 °C to +60 °C operation.
-
Seamless DCS Integration: Plug-and-play with Yokogawa’s CENTUM VP/CS 3000 and ProSafe-RS systems over Vnet/IP.
-
Easy Configuration & Diagnostics: Built-in monitoring tools accelerate commissioning and reduce downtime.
Frequently Asked Questions (FAQ)
-
What is the primary purpose of the SSB401-S53?
It acts as a slave interface, converting diverse field signals into standardized ESB data streams for Yokogawa DCS. -
Which signals can I connect?
Voltage, current, thermocouples, RTDs, and digital I/O types. -
How do I power the module?
It requires a 24 V DC supply, with typical consumption below 0.5 A. -
Can I mix protocols on one ESB network?
Yes—depending on firmware, it supports ESB, PROFIBUS DP, DeviceNet, and CANopen. -
What is the maximum network length?
Network length follows ESB specifications; use repeaters (e.g., SNT411/SNT511) for distances >100 m. -
How is configuration performed?
Via Yokogawa’s engineering software (ENG) over Vnet/IP; no DIP-switches required. -
What maintenance is needed?
Periodic verification of signal accuracy and firmware updates; no moving parts. -
Is it SIL-rated for safety loops?
Yes—when used with ProSafe-RS hardware, it supports SIL 3 applications. -
What’s the ambient temperature range?
–10 °C to +60 °C, suitable for most plant environments. -
How do I diagnose communication issues?
Use built-in LED indicators and software diagnostics in Yokogawa’s DCS suite.
Related Models (Same or Compatible Series)
| Model | Description |
|---|---|
| SSB401-13 | ESB Bus Interface Slave Module, basic analog version |
| SSB401-53 | ESB Bus Interface Slave, enhanced digital I/O variant |
| SEC401-11 | ESB Bus Coupler Module for master-side network interface |
| SEC402-51 | Redundant ESB Bus Coupler Module |
| SPW482-13 | Serial Protocol Converter Module |
| SPW482-53 | High-speed Serial Protocol Converter |
Popular Yokogawa Models
| Model | Application |
|---|---|
| SDV541-S63 | High-density analog input/output module |
| SNB10D-225/CU2T | Safety Node Unit with dual-redundant CPU |
| SNT401-53 | Optical ESB Bus Repeater Slave Module |
| SNT411 | Optical ESB Bus Repeater Master Module |
| S2EN501 | N-ESB Bus Interface Module |
| S2MMM843-SS1030 | CENTUM VP Main Cabinet Module |
Frequently Asked Questions (FAQ)
-
What is the primary purpose of the SSB401-S53?
It acts as a slave interface, converting diverse field signals into standardized ESB data streams for Yokogawa DCS. -
Which signals can I connect?
Voltage, current, thermocouples, RTDs, and digital I/O types. -
How do I power the module?
It requires a 24 V DC supply, with typical consumption below 0.5 A. -
Can I mix protocols on one ESB network?
Yes—depending on firmware, it supports ESB, PROFIBUS DP, DeviceNet, and CANopen. -
What is the maximum network length?
Network length follows ESB specifications; use repeaters (e.g., SNT411/SNT511) for distances >100 m. -
How is configuration performed?
Via Yokogawa’s engineering software (ENG) over Vnet/IP; no DIP-switches required. -
What maintenance is needed?
Periodic verification of signal accuracy and firmware updates; no moving parts. -
Is it SIL-rated for safety loops?
Yes—when used with ProSafe-RS hardware, it supports SIL 3 applications. -
What’s the ambient temperature range?
–10 °C to +60 °C, suitable for most plant environments. -
How do I diagnose communication issues?
Use built-in LED indicators and software diagnostics in Yokogawa’s DCS suite.
Related Models (Same or Compatible Series)
| Model | Description |
|---|---|
| SSB401-13 | ESB Bus Interface Slave Module, basic analog version |
| SSB401-53 | ESB Bus Interface Slave, enhanced digital I/O variant |
| SEC401-11 | ESB Bus Coupler Module for master-side network interface |
| SEC402-51 | Redundant ESB Bus Coupler Module |
| SPW482-13 | Serial Protocol Converter Module |
| SPW482-53 | High-speed Serial Protocol Converter |
Popular Yokogawa Models
| Model | Application |
|---|---|
| SDV541-S63 | High-density analog input/output module |
| SNB10D-225/CU2T | Safety Node Unit with dual-redundant CPU |
| SNT401-53 | Optical ESB Bus Repeater Slave Module |
| SNT411 | Optical ESB Bus Repeater Master Module |
| S2EN501 | N-ESB Bus Interface Module |
| S2MMM843-SS1030 | CENTUM VP Main Cabinet Module |
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666033393 | |||||||
| +8613666033393 | ||||||||
| 13666033393 | ||||||||
| Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.
As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.
Excellent PLC