| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666033393 | |||||||
| +8613666033393 | ||||||||
| 13666033393 | ||||||||
| Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Allen Bradley 1756-OB16I ControlLogix Isolated Digital Output Module
- Product Details
- FAQs
- Related
- Contact Us
- Packing & Delivery
- Product Ratings
Product Introduction
The Allen-Bradley 1756-OB16I is a ControlLogix isolated digital output module designed for DC control applications that require enhanced electrical separation between the control system and field devices. As part of the ControlLogix I/O family, this module combines high channel density, flexible sink/source operation, and robust isolation, making it suitable for complex industrial control environments.
The 1756-OB16I is commonly selected for systems where protection against ground potential differences, electrical noise, or transient voltages is critical. By providing channel-to-backplane isolation, the module helps maintain signal integrity and improves overall system reliability, especially in installations with mixed power domains or sensitive control equipment.
Product Specifications
| Parameter | Description |
|---|---|
| Product Type | ControlLogix Isolated Digital Output Module |
| Output Type | Isolated DC Digital Output |
| Number of Outputs | 16 digital outputs |
| Operating Voltage Range | 10–30 VDC |
| Rated Output Voltage | 12–24 VDC |
| Output Configuration | Sink / Source selectable |
| Isolation Voltage | 250 V continuous |
| Power Dissipation | 3.6 W |
| Signal Switching | Electronic DC switching |
| Chassis Compatibility | ControlLogix chassis |
| Control Platform | ControlLogix automation system |
| Industrial Rating | Designed for industrial control environments |
| Dimensions | 144.5 × 34.6 × 130.18 mm |
| Weight | 0.181 kg |
Applications
• Used for isolated control of DC actuators and interface devices, including relays, solenoid valves, and signaling equipment
• Suitable for systems with mixed grounding schemes where electrical separation is required to protect the controller
• Applied in process automation and manufacturing systems exposed to electrical noise or voltage transients
• Commonly implemented in material handling, packaging, and assembly lines requiring reliable DC output control
• Ideal for applications that demand high system integrity and protection against ground loops
Advantages
• Channel-to-backplane isolation significantly improves system protection and noise immunity
• Flexible sink/source output design supports a wide range of field device wiring methods
• 16-channel density optimizes ControlLogix chassis space and reduces hardware count
• Wide DC operating voltage range enhances compatibility with standard industrial power supplies
• Low power dissipation supports efficient thermal management inside control cabinets
• Designed for stable, long-term operation in demanding industrial environments
FAQ
-
What is the primary benefit of using an isolated digital output module?
Isolation protects the controller and backplane from field-side electrical disturbances, improving overall system stability. -
How does sink/source capability affect wiring flexibility?
It allows the module to be wired for either sinking or sourcing operation, accommodating different field device requirements. -
Can the 1756-OB16I be used in systems with multiple ground references?
Yes, the isolation design makes it well suited for installations where ground potential differences may exist. -
How does the module handle electrical noise in industrial environments?
The isolation barrier and internal circuitry help prevent noise and transients from propagating into the control system. -
Is the module suitable for driving inductive DC loads?
Yes, it can control inductive loads such as relays and solenoids when proper suppression techniques are applied. -
How is output status monitored by the ControlLogix controller?
Output states are communicated through the ControlLogix backplane, enabling real-time monitoring and diagnostics. -
Does isolation affect output response time?
The isolation design does not significantly impact response time for standard industrial digital output applications. -
Can isolated and non-isolated output modules coexist in the same chassis?
Yes, both types of modules can be installed together within a ControlLogix chassis when properly configured. -
What considerations are important when designing wiring for isolated outputs?
Maintaining proper separation of field wiring and following grounding best practices are essential for optimal performance. -
How does power dissipation influence cabinet design?
Lower power dissipation helps reduce internal cabinet temperatures, supporting improved thermal management and component longevity.
Related Models
| Model | Description |
|---|---|
| 1756-OB16 | Standard DC digital output module |
| 1756-OB16E | Enhanced DC digital output module |
| 1756-OB32 | High-density DC digital output module |
| 1756-OA16 | 16-point AC digital output module |
| 1756-OW16I | Isolated relay output module |
| 1756-IB16 | 16-point DC digital input module |
Popular Models
| Model | Description |
|---|---|
| 1756-L81E | ControlLogix high-performance controller |
| 1756-L83E | Advanced ControlLogix controller |
| 1756-EN2TR | EtherNet/IP communication module |
| 1756-PA72 | ControlLogix power supply |
| 1756-IF16 | 16-channel analog input module |
| 1756-A10 | 10-slot ControlLogix chassis |
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666033393 | |||||||
| +8613666033393 | ||||||||
| 13666033393 | ||||||||
| Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.
As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.
Excellent PLC
