| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666033393 | |||||||
| +8613666033393 | ||||||||
| 13666033393 | ||||||||
| Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Allen Bradley 1756-N2 ControlLogix Empty Slot Filler
- Product Details
- FAQs
- Related
- Contact Us
- Packing & Delivery
- Product Ratings
Product Introduction
The Allen-Bradley 1756-N2 is a ControlLogix empty slot filler module designed to maintain proper airflow, structural integrity, and system organization within a ControlLogix chassis. Although it does not perform any electrical or control function, it plays an important mechanical and environmental role in maintaining system reliability.
In modular PLC systems, unused chassis slots can disrupt cooling patterns and reduce mechanical protection. The 1756-N2 is installed in empty positions to ensure that airflow remains consistent across active modules. This helps prevent localized overheating and maintains optimal operating conditions inside the enclosure.
Manufactured by Rockwell Automation, this filler module is fully compatible with all ControlLogix chassis types and installs exactly like a standard I/O or communication module. It is widely used in projects where future expansion is planned, allowing engineers to reserve slots without compromising cabinet standards.
Product Specifications
| Parameter | Description |
|---|---|
| Model | 1756-N2 |
| Brand | Allen-Bradley |
| Series | ControlLogix |
| Module Type | Empty Slot Filler |
| Compatibility | ControlLogix 1756 Chassis |
| Installation Method | Slot-mounted, backplane mechanical engagement |
| Material | Industrial-grade molded plastic |
| Color | Black |
| Operating Temperature | -25°C to +60°C |
| Storage Temperature | -40°C to +85°C |
| Dimensions | 120 × 35 × 100 mm |
| Weight | 0.05 kg |
Applications
• Maintains proper airflow distribution inside ControlLogix chassis to support thermal management
• Used in systems where future module expansion is planned, reserving space without affecting system integrity
• Ensures mechanical stability and protection of the backplane connectors
• Applied in power generation, oil & gas, manufacturing, and process automation cabinets
• Supports compliance with panel design standards requiring closed or protected unused slots
Advantages
• Improves thermal performance by maintaining correct chassis airflow patterns
• Provides clean and professional cabinet layout, enhancing maintenance efficiency
• Simple installation with no wiring or configuration required
• Protects backplane from dust, debris, and accidental contact
• Fully compatible with all standard ControlLogix chassis configurations
FAQ
-
Does the 1756-N2 require configuration in RSLogix or Studio 5000?
No configuration is required. The module has no electronic function and is not recognized by the controller. -
Can the filler module remain installed during system power operation?
Yes, it is designed to be installed and remain in place during normal system operation. -
Does the 1756-N2 connect to the backplane electrically?
No electrical connection is made. It only provides mechanical engagement. -
Is it necessary to install fillers in every unused slot?
It is recommended when airflow management or environmental protection is required. -
Can the module affect system performance?
It does not affect processing or communication performance, but it supports proper thermal conditions. -
Is the 1756-N2 compatible with redundant ControlLogix systems?
Yes, it can be used in redundant chassis systems without issue. -
Can it be reused after removal?
Yes, provided there is no physical damage. -
Does it provide EMI shielding?
It offers basic enclosure coverage but does not function as an active EMI filter. -
Is the installation tool-free?
Yes, it installs using the same locking mechanism as standard ControlLogix modules. -
Can it be used in hazardous area installations?
It follows the chassis certification. Hazardous approval depends on the overall system configuration.
Related Models
| Model | Description |
|---|---|
| 1756-N1 | ControlLogix Empty Slot Filler (Alternate Type) |
| 1756-A4 | 4-Slot ControlLogix Chassis |
| 1756-A7 | 7-Slot ControlLogix Chassis |
| 1756-A10 | 10-Slot ControlLogix Chassis |
| 1756-A13 | 13-Slot ControlLogix Chassis |
| 1756-A17 | 17-Slot ControlLogix Chassis |
Popular Models
| Model | Description |
|---|---|
| 1756-L81E | ControlLogix 5580 Controller |
| 1756-EN2T | EtherNet/IP Communication Module |
| 1756-IB16 | 16-Point Digital Input Module |
| 1756-OB16E | 16-Point Digital Output Module |
| 1756-IF8 | 8-Channel Analog Input Module |
| 1756-OF8 | 8-Channel Analog Output Module |
| Company Information | ||||||||
| [email protected] | ||||||||
| Mobile | +8613666033393 | |||||||
| +8613666033393 | ||||||||
| 13666033393 | ||||||||
| Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China | |||||||
Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.
As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.
Excellent PLC
