GE IS200EGDMH1A Exciter Ground Detector Module Excellent PLC Co.,Ltd

PLC and DCS professional supplier

GE IS200EGDMH1A Exciter Ground Detector Module

Manufacturer:GE

Product Number:IS200EGDMH1A

Product Type:Exciter Ground Detector Module

Origin:USA

Dimensions:267 x 216 x 25 mm

Weight:0.8 kg

Views:144

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24


  • Product Details
  • FAQs
  • Related
  • Contact Us
  • Packing & Delivery
  • Product Ratings
Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

GE IS200EGDMH1A Exciter Ground Detector Module

Product Introduction

The GE IS200EGDMH1A is an Exciter Ground Detector Module developed by General Electric for use in GE’s Mark VI and EX2100 excitation control systems. Its primary role is to monitor and detect ground faults in the generator field or exciter circuit. Ground faults are a serious safety hazard that can lead to equipment damage, unplanned outages, or catastrophic failure if not detected early.

The IS200EGDMH1A module continuously monitors the generator field winding for insulation degradation or unintended grounding. It provides a real-time analog signal that represents the resistive path to ground, enabling the control system to take protective action if the resistance drops below a safe threshold.

This board is especially critical in high-voltage generator excitation systems, where even a minor insulation failure can have significant consequences. Designed with rugged industrial specifications, the EGDM board offers high sensitivity, fast response time, and reliable performance in demanding environments.


Technical Specifications

Parameter Details
Manufacturer General Electric (GE)
Part Number IS200EGDMH1A
Product Type Exciter Ground Detector Module
Series Mark VI, EX2100
Primary Function Detects ground faults in the exciter field circuit
Input Voltage 24 VDC (nominal)
Output Signal Analog DC signal (resistance to ground)
Monitoring Range 0–10 MΩ (typical)
Response Time <100 ms (typical)
Signal Isolation Galvanic isolation
Mounting Method Panel or rack-mounted
Connector Type Multi-pin ribbon and terminal block
Operating Temperature 0°C to +60°C
Storage Temperature -40°C to +85°C
Humidity Range 5% to 95% non-condensing
Dimensions (L x W x H) 267 x 216 x 25 mm
Weight 0.8 kg
Certifications UL, CE, RoHS compliant

Applications

The GE IS200EGDMH1A module is used in a variety of power generation and industrial settings, including:

  • Synchronous generator protection systems

  • Excitation systems in thermal, hydro, and nuclear plants

  • Large utility substations with rotating equipment

  • Field insulation monitoring in high-voltage applications

  • Safety-critical generator control environments

  • Remote diagnostics and field circuit health monitoring

  • Retrofit of older systems with modern detection modules


Product Advantages

  • Early Ground Fault Detection: Identifies insulation failures before they become critical, helping prevent severe equipment damage.

  • High Sensitivity Monitoring: Capable of detecting low-level resistive paths to ground, which many traditional systems may overlook.

  • Fast Response Time: Triggers alarms or protective shutdowns rapidly, helping to isolate faults in real time.

  • Robust Industrial Design: Built to withstand vibration, electrical interference, and high operational loads in power generation environments.

  • Integrated System Compatibility: Fully supported by GE’s Mark VI and EX2100 platforms, simplifying wiring and configuration.

  • Signal Integrity Assurance: Galvanic isolation and filtering provide clean analog outputs with minimal noise.

  • Modular Serviceability: Designed for quick installation and replacement with minimal system disruption.

  • Low Maintenance Requirements: Once installed, requires only basic periodic checks as part of standard system maintenance.


Frequently Asked Questions (FAQ)

  1. What is the primary function of the IS200EGDMH1A board?
    It continuously monitors the generator field circuit for ground faults by measuring resistance to ground and signaling when faults occur.

  2. Which systems is this board compatible with?
    It is designed for use in GE’s Mark VI and EX2100 excitation control systems.

  3. Why is ground fault detection important in excitation systems?
    A ground fault can cause damage to the generator or excitation equipment. Early detection helps prevent unsafe conditions and unplanned downtime.

  4. How is the output from this module used by the control system?
    The board outputs an analog signal that represents the resistance to ground; the control system uses this to initiate alarms or protective actions.

  5. Does the module include signal isolation?
    Yes, it features galvanic isolation to prevent interference and protect connected circuits.

  6. What is the response time for detecting faults?
    The board typically detects and responds to a fault in less than 100 milliseconds.

  7. Can this board be used for retrofitting older systems?
    Yes, it is often used to upgrade existing GE excitation systems to improve ground fault monitoring reliability.

  8. How often does this board require maintenance?
    Minimal maintenance is needed—routine signal verification and connector inspections are typically sufficient.

  9. What environmental protections does this board have?
    It is designed to operate in industrial environments, tolerating wide temperature ranges and high humidity.

  10. How is installation typically carried out?
    Installation involves mounting the board in the designated panel or rack slot, connecting the terminal and ribbon cables, and configuring the system input channels accordingly.


Related Models (Same Series or Function)

Model Number Description Compatibility
IS200EGDMH1B Updated version of the Exciter Ground Detector Mark VI, EX2100
IS200EDEXG1B Exciter De-Excitation Board Mark VI, EX2100
IS200EDCFG1B Exciter DC Feedback Board Mark VIe, EX2100
IS200EDFFH1A DC Feedback Fan Control Board Mark VIe
IS200DSPXH1D Digital Signal Processor Module Mark VIe
IS200EDSPX1A Signal Processing and Filtering Module Mark VIe

Popular GE Models (Same Brand)

Model Number Description Application
IS200VCMIH1B VME Communication Interface Module Mark VI / VIe Controllers
IS200TREGH1B Trip Emergency Relay Interface Module Generator Protection Systems
IS200TBTCH1C Terminal Board for Contact Inputs I/O Expansion
IS200WROBH1A Wireless Relay Output Board Digital Output Interface
IS215UCVEM01A Control Processor Module Mark VI Controllers
IS200TRLYH1B Relay Output Board Turbine and Generator I/O

Frequently Asked Questions (FAQ)

  1. What is the primary function of the IS200EGDMH1A board?
    It continuously monitors the generator field circuit for ground faults by measuring resistance to ground and signaling when faults occur.

  2. Which systems is this board compatible with?
    It is designed for use in GE’s Mark VI and EX2100 excitation control systems.

  3. Why is ground fault detection important in excitation systems?
    A ground fault can cause damage to the generator or excitation equipment. Early detection helps prevent unsafe conditions and unplanned downtime.

  4. How is the output from this module used by the control system?
    The board outputs an analog signal that represents the resistance to ground; the control system uses this to initiate alarms or protective actions.

  5. Does the module include signal isolation?
    Yes, it features galvanic isolation to prevent interference and protect connected circuits.

  6. What is the response time for detecting faults?
    The board typically detects and responds to a fault in less than 100 milliseconds.

  7. Can this board be used for retrofitting older systems?
    Yes, it is often used to upgrade existing GE excitation systems to improve ground fault monitoring reliability.

  8. How often does this board require maintenance?
    Minimal maintenance is needed—routine signal verification and connector inspections are typically sufficient.

  9. What environmental protections does this board have?
    It is designed to operate in industrial environments, tolerating wide temperature ranges and high humidity.

  10. How is installation typically carried out?
    Installation involves mounting the board in the designated panel or rack slot, connecting the terminal and ribbon cables, and configuring the system input channels accordingly.

Related Models (Same Series or Function)

Model Number Description Compatibility
IS200EGDMH1B Updated version of the Exciter Ground Detector Mark VI, EX2100
IS200EDEXG1B Exciter De-Excitation Board Mark VI, EX2100
IS200EDCFG1B Exciter DC Feedback Board Mark VIe, EX2100
IS200EDFFH1A DC Feedback Fan Control Board Mark VIe
IS200DSPXH1D Digital Signal Processor Module Mark VIe
IS200EDSPX1A Signal Processing and Filtering Module Mark VIe

Popular GE Models (Same Brand)

Model Number Description Application
IS200VCMIH1B VME Communication Interface Module Mark VI / VIe Controllers
IS200TREGH1B Trip Emergency Relay Interface Module Generator Protection Systems
IS200TBTCH1C Terminal Board for Contact Inputs I/O Expansion
IS200WROBH1A Wireless Relay Output Board Digital Output Interface
IS215UCVEM01A Control Processor Module Mark VI Controllers
IS200TRLYH1B Relay Output Board Turbine and Generator I/O

GE IS200EGDMH1A Exciter Ground Detector Module

Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.

As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.

Click to rate this post!
[Total: 0 Average: 0]

Prev:

Next:

Leave a message