Allen Bradley 1747-BSN Backup Scanner Module Excellent PLC Co.,Ltd

PLC and DCS professional supplier

Allen Bradley 1747-BSN Backup Scanner Module

Manufacturer:Allen Bradley

Product Number:1747-BSN

Product Type:Backup Scanner Module

Origin:USA

Dimensions:144.5 × 34.6 × 130.18 mm

Weight:0.45 kg

Views:135

Payment Methods:T/T, PayPal, Western Union

Condition:New & In Stock

Shipping Port:Xiamen, China

Warranty:1 Year

Lead Time:1-3 Working Days

Certificate:COO

Courier partners:DHL, UPS, TNT, FedEx and EMS.

Business hours:7*24


New In Stock Original 100% New Unbelievable Prices! Fast Shipping! 30-Day Returns! 12-Month Warranty Trusted supplier Over 100,000 Automation Parts Available! 100% Original and Brand New !
  • Product Details
  • FAQs
  • Related
  • Contact Us
  • Packing & Delivery
  • Product Ratings

Allen Bradley 1747-BSN Backup Scanner Module

Product Introduction

The Allen Bradley 1747-BSN Backup Scanner Module is a redundancy-focused communication module designed for SLC 500 control systems using Remote I/O (RIO) networks. Its primary role is to operate as a backup scanner, automatically assuming control of the Remote I/O network if the primary scanner becomes unavailable, thereby maintaining continuous system operation.

This module is engineered for high-availability industrial applications where uninterrupted I/O communication is critical. By supporting seamless switchover, the 1747-BSN minimizes process disruptions and enhances overall system reliability. It integrates directly into SLC 500 chassis architectures and works in conjunction with primary scanner modules to form a robust redundant communication solution.

The 1747-BSN also supports RS-232 and DH+ (Data Highway Plus) interfaces, allowing flexible communication and diagnostics within complex automation systems.


Product Specifications

Parameter Description
Product Type Backup Scanner Module
System Series Allen-Bradley SLC 500
Primary Function Backup control of Remote I/O network
Communication Protocol Remote I/O (RIO)
Network Redundancy Role Automatic backup scanner
Supported Interfaces RS-232, DH+ (Data Highway Plus)
Data Handling Cyclic and deterministic I/O data exchange
Power Supply Voltage 5 VDC
Current Consumption 800 mA
Chassis Installation SLC 500 rack-mounted module
Diagnostics Capability Network status and fault indication
Dimensions 144.5 × 34.6 × 130.18 mm
Weight 0.45 kg

Applications

Redundant Remote I/O systems, ensuring continuous I/O communication in critical processes.

Manufacturing automation, supporting high-availability PLC architectures.

Process control environments, minimizing downtime caused by communication module failures.

Industrial control networks, integrating backup scanning capability for Remote I/O racks.

Legacy SLC 500 systems, enhancing reliability without major system redesign.


Advantages

Automatic redundancy support, maintaining Remote I/O control during primary scanner failure.

Deterministic communication, preserving predictable I/O update cycles.

Seamless SLC 500 integration, designed specifically for existing chassis architectures.

Support for DH+ and RS-232, enabling flexible communication and diagnostics.

Industrial-grade reliability, suitable for continuous-duty applications.

Reduced system downtime, improving overall plant availability.

FAQ

  1. What is the main purpose of the 1747-BSN module?
    It acts as a backup scanner to maintain control of the Remote I/O network if the primary scanner fails.

  2. Which control systems support this module?
    It is designed for Allen-Bradley SLC 500 systems using Remote I/O networks.

  3. Does the module operate as a primary scanner?
    No, it functions specifically as a backup scanner in redundant configurations.

  4. How does the switchover process occur?
    The module automatically assumes scanning control when the primary scanner becomes unavailable.

  5. What communication protocols are supported?
    It supports Remote I/O communication, along with RS-232 and DH+ interfaces.

  6. Is the communication deterministic?
    Yes, Remote I/O communication provides cyclic and predictable data exchange.

  7. Does the module provide diagnostic information?
    Yes, it offers status and fault indication for network monitoring.

  8. Is the module suitable for continuous industrial operation?
    Yes, it is engineered for continuous-duty use in industrial environments.

  9. Can it be used in system retrofit projects?
    Yes, it is commonly used to enhance reliability in existing SLC 500 installations.

  10. How does the module improve overall system reliability?
    By providing automatic backup scanning, it ensures uninterrupted I/O communication during failures.

Related Models

Model Description
1747-SN Primary Remote I/O Scanner Module
1747-ASB Remote I/O Adapter Module
1747-L553 SLC 5/05 Processor
1747-L552 SLC 5/04 Processor
1746-ASB Remote I/O Adapter
1746-A4 SLC 500 I/O Chassis

Popular Models

Model Application Focus
1747-L553 SLC 5/05 PLC Processor
1747-L552 SLC 5/04 PLC Processor
1747-SN Remote I/O Scanner
1746-IB16 Digital Input Module
1746-OB16 Digital Output Module
1746-NI4 Analog Input Module

Allen Bradley 1747-BSN Backup Scanner Module

Company Information
E-mail [email protected]
Mobile +8613666033393
Whatsapp +8613666033393
WeChat 13666033393
Add Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China

Excellent PLC Co., Ltd. has a large number of brand new and original PLC and DCS spare parts, with more than 60 cooperative countries. All products are guaranteed for 1 year and delivered to you by high-quality express. We are committed to using the best products and the most favorable prices to meet the needs and friendship of our customers. We have won the trust of thousands of customers, including these excellent customers.

As for the delivery time, when we receive your order requirements, we will arrange for warehouse personnel to test and verify the products. After you place the order, we will send it to you within 24 hours.

Click to rate this post!
[Total: 0 Average: 0]

Prev:

Next:

Leave a message