Product Introduction
The Schneider Electric 140NWM10000 is an Ethernet Network TCP/IP Module designed to integrate Modicon Quantum PLCs into Ethernet networks. This module facilitates seamless communication between PLCs and other networked devices, supporting protocols such as Modbus TCP/IP and SNMP. Equipped with a FactoryCast HMI, it allows for real-time monitoring and control via web browsers, enhancing system transparency and accessibility.
Technical Specifications
| Parameter | Details |
|---|---|
| Product Type | Ethernet Network TCP/IP Module |
| Series | Modicon Quantum |
| Part Number | 140NWM10000 |
| Communication Protocols | Ethernet TCP/IP, Modbus TCP, SNMP |
| Web Server | FactoryCast HMI Active, Class D10 |
| Physical Interfaces | RJ45 (10BASE-T/100BASE-TX), MT-RJ (100BASE-FX) |
| Transmission Rate | 10/100 Mbps |
| Power Supply | Via rack power supply |
| Current Consumption | 750 mA at 5 V DC |
| Operating Temperature | 0°C to 60°C |
| Storage Temperature | -40°C to 85°C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Dimensions (W x H x D) | 103.9 × 40.3 × 250 mm |
| Weight | 0.345 kg |
| Certifications | CE, UL, CSA |
| Diagnostic Indicators | LEDs for data rate, collision detection, module status, etc. |
Product Applications
The 140NWM10000 module is suitable for various industrial applications requiring robust and reliable Ethernet communication:
-
Manufacturing Plants: Integrating PLCs with SCADA systems for real-time monitoring and control.
-
Process Automation: Facilitating communication between distributed control systems and field devices.
-
Energy Management: Monitoring and controlling energy distribution networks.
-
Water Treatment Facilities: Managing and automating water purification and distribution processes.
-
Building Automation: Controlling HVAC, lighting, and security systems through centralized networks.
Product Advantages
-
Enhanced Connectivity: Supports multiple communication protocols, ensuring compatibility with various devices.
-
Integrated Web Server: FactoryCast HMI allows for remote monitoring and control via standard web browsers.
-
High-Speed Communication: 10/100 Mbps transmission rates ensure rapid data exchange.
-
Robust Diagnostics: LED indicators provide immediate status updates, facilitating quick troubleshooting.
-
Compact Design: Small form factor allows for easy integration into existing systems without significant space requirements.
Frequently Asked Questions (FAQ)
-
Can the 140NWM10000 module be used in both star and linear Ethernet topologies?
Yes, it can operate in either topology, provided the connected switches and devices support the appropriate standards. -
How can I access the built-in web server on the module?
Connect the module to your network, assign it an IP address, and access it via any modern browser using the FactoryCast web interface. -
Is VLAN tagging supported on the Ethernet port?
No, the 140NWM10000 does not support VLAN tagging; it’s designed for standard Modbus TCP/IP environments. -
What happens if the Ethernet connection is lost during operation?
Communication will be interrupted, and depending on the PLC programming, it may trigger fault routines or switch to fail-safe mode. -
Does the module support SNMP traps for monitoring?
Yes, it supports SNMP and can be configured to send traps to monitoring systems for status and diagnostic reporting. -
Can this module be used with third-party SCADA software?
Yes, any SCADA software that supports Modbus TCP/IP communication can interface with the module. -
How is the IP address configured on the 140NWM10000?
IP address can be set manually via the configuration utility or assigned dynamically through a DHCP server. -
Does it support both copper and fiber Ethernet interfaces?
Yes, it provides both RJ45 (10/100Base-T) and MT-RJ (100Base-FX) ports to support copper and fiber media. -
Can the module be hot-swapped while the system is running?
No, it is not hot-swappable. Always power down the rack before inserting or removing the module. -
What is the recommended method to diagnose communication issues with this module?
Start with the LED indicators on the front panel to check link/activity status, then use the FactoryCast diagnostic pages to identify network errors, mismatched IP settings, or protocol mismatches.
Related Models (Same Series or Functional Compatibility)
| Model | Description | Key Function |
|---|---|---|
| 140NOE77100 | Ethernet Network TCP/IP Module | Standard Ethernet communication |
| 140NOE77101 | Ethernet Network TCP/IP Module with Web Server | Enhanced web-based diagnostics |
| 140NOE77111 | Advanced Ethernet Module | Supports additional protocols |
| 140CRP93100 | RIO Head Adapter Module | Central connection for RIO networks |
| 140NOM21200 | DIO Head-End Adapter | Interfaces with distributed I/O systems |
| 140NWM10000 | Ethernet Network TCP/IP Module | Standard Ethernet communication module |
Popular Schneider Electric Models (Other Series / High-Demand)
| Model | Description | Application Area |
|---|---|---|
| BMXP342020 | Modicon M340 CPU Module | Mid-range control systems |
| TM221CE24R | Modicon TM221 Logic Controller | Small automation and machine control |
| BMENOC0301 | M580 Ethernet Communication Module | High-speed Ethernet networking |
| BMXDDI1602 | M340 Digital Input Module | 16-point digital input handling |
| TSXP57203M | TSX Premium CPU Module | Legacy control systems |
| BMEP584040 | Modicon M580 Performance CPU | Advanced high-end process automation |
Excellent PLC