Schneider TSXWMY100 Ethernet TCP/IP Module
The Schneider TSXWMY100 is a communication module designed for Modicon TSX Micro and Premium PLC systems, enabling seamless Ethernet TCP/IP connectivity. It offers reliable data exchange between PLCs and supervisory systems over industrial networks.
Technical Specifications
| Parameter | Description |
|---|---|
| Product Type | Ethernet TCP/IP Communication Module |
| Communication Protocol | Ethernet TCP/IP |
| Transmission Rate | 10/100 Mbps (auto-sensing) |
| Connector Type | RJ45 |
| Supported PLCs | Modicon TSX Micro, TSX Premium |
| Diagnostic LED | Yes |
| Power Supply | 5 VDC from PLC backplane |
| Configuration Tool | Unity Pro / PL7 |
| Dimensions (W×H×D) | 260 × 180 × 60 mm |
| Weight | 0.44 kg |
Applications
-
Real-time control and data acquisition in industrial automation
-
Communication between Modicon PLCs and SCADA/HMI systems
-
Integration into Ethernet-based factory networks
-
Remote monitoring and diagnostics
Advantages
-
Simple integration into existing Modicon TSX systems
-
Fast and reliable Ethernet communication
-
Supports standard Ethernet network diagnostics
-
Compact design for easy installation
-
Reduces wiring by enabling centralized data collection
Frequently Asked Questions (FAQ)
Q1: What PLCs are compatible with the TSXWMY100 module?
A1: It is compatible with Schneider Modicon TSX Micro and TSX Premium PLCs.
Q2: Can the module be used in a redundant network?
A2: No, TSXWMY100 does not support network redundancy features.
Q3: What is the default IP address of the TSXWMY100?
A3: The default IP can be configured using Unity Pro or PL7 software.
Q4: Does it support Modbus TCP?
A4: Yes, it supports Modbus TCP communication over Ethernet.
Q5: Is the TSXWMY100 hot-swappable?
A5: No, the module must be powered down before replacement.
Q6: Can I monitor diagnostics via web browser?
A6: No, it does not have a built-in web server. Diagnostics must be accessed via software tools.
Q7: What cable should be used for Ethernet connection?
A7: Use standard Cat5e or Cat6 Ethernet cables with RJ45 connectors.
Q8: Is it suitable for outdoor use?
A8: No, it should be installed in a control cabinet within a protected indoor environment.
Q9: What is the max cable length supported?
A9: It supports Ethernet cable lengths up to 100 meters.
Q10: Does it require a separate power supply?
A10: No, it draws power directly from the PLC backplane.
Related Schneider TSX/Communication Modules
| Model | Description | Protocol | Dimensions (mm) | Weight |
|---|---|---|---|---|
| TSXETY4103 | Ethernet TCP/IP module for TSX57 PLC | Ethernet TCP/IP | 260 × 180 × 60 | 0.45 kg |
| TSXETY5103 | Ethernet module with web server | Modbus TCP/IP | 260 × 180 × 60 | 0.48 kg |
| TSXCAY21 | CANopen communication module | CANopen | 260 × 180 × 60 | 0.42 kg |
| TSXCUSB485 | USB to RS485 converter | Serial (RS485) | 120 × 80 × 30 | 0.20 kg |
| TSXCTY2A | Terminal block for serial modules | Serial connection | 80 × 30 × 20 | 0.10 kg |
| TSXCPP110 | Profibus DP communication module | Profibus DP | 260 × 180 × 60 | 0.46 kg |
Popular Schneider Models
| Model | Description | Application Area | Dimensions (mm) | Weight |
|---|---|---|---|---|
| BMXP342020 | Modicon M340 CPU module | Automation controller | 150 × 145 × 60 | 0.38 kg |
| TM241CEC24T | Modicon M241 logic controller | Machine automation | 160 × 125 × 70 | 0.50 kg |
| TM221ME16T | Modicon M221 logic controller | Compact control | 130 × 100 × 70 | 0.45 kg |
| BMXNOE0100 | Ethernet communication module for M340 | Network communication | 130 × 145 × 50 | 0.40 kg |
| HMISTU855 | HMI touch screen 5.7” | Operator interface | 180 × 130 × 50 | 0.70 kg |
| ATV320U15M2B | Altivar 320 variable speed drive | Motor control | 143 × 154 × 154 | 1.90 kg |